Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Evaluation of non-parametric identification techniques in second order models plus dead time

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 6 (2020)

DOI
10.11591/ijece.v10i6.pp6340-6348
ISSN
2722-2578, 2088-8708
Published
2020-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In this paper, a set of non-parametric identification techniques are used in order to obtain second order models plus dead time for an underdamped system. Initially, non-parametric techniques were used to identify the system from the temperature data of a coal-heated oven. In this case, the identification techniques proposed by Stark, Jahanmiri - Fallahi and Ogata were used, which require obtaining two or three points of the step response for the system under study. In addition, the Matlab PID Tuner app was used to identify the underdamped system and compare the results with the other methods. The results show that the PID Tuner and the method proposed by Ogata are the ones that best represent the dynamics of the underdamped system, taking into account the values for the Integral Absolute Error (IAE) and the correlation coefficient. With the Stark method an IAE of 181.56 was obtained, while with the PID Tuner the best performance was achieved with an IAE of 21.59. In terms of the results obtained with the cross correlation, the best performance was achieved with the PID tuner and the Stark method.

Collaboration network of the authors

13 authors · 25 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad del Magdalena
  • Universidad Autónoma de Bucaramanga
  • Universidad del Norte
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Carlos ArizmendiUniversidad Autónoma de Bucaramanga1
Yecid MuñozAffiliation unknown1
Carlos RoblesUniversidad del Magdalena1
Jordan GuillotUniversidad del Magdalena1
Diego Restrepo-LealUniversidad del Magdalena1
Ingrid OliverosUniversidad del Norte1
Paola Andrea Niño-SuárezAffiliation unknown1
Leydis Marcela Maestre‐MatosUniversidad del Magdalena1
Manuel Manjarres-RiveraUniversidad del Magdalena1
Jose Navarro-MenesesUniversidad del Magdalena1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Evaluation of non-parametric identification techniques in second order models plus dead time</dc:title><dc:creator>Robles-Algarín, Carlos</dc:creator><dc:creator>Rodríguez, Omar</dc:creator><dc:creator>Ospino, Adalberto</dc:creator><dc:description>&lt;jats:p&gt;In this paper, a set of non-parametric identification techniques are used in order to obtain second order models plus dead time for an underdamped system. Initially, non-parametric techniques were used to identify the system from the temperature data of a coal-heated oven. In this case, the identification techniques proposed by Stark, Jahanmiri - Fallahi and Ogata were used, which require obtaining two or three points of the step response for the system under study. In addition, the Matlab PID Tuner app was used to identify the underdamped system and compare the results with the other methods. The results show that the PID Tuner and the method proposed by Ogata are the ones that best represent the dynamics of the underdamped system, taking into account the values for the Integral Absolute Error (IAE) and the correlation coefficient. With the Stark method an IAE of 181.56 was obtained, while with the PID Tuner the best performance was achieved with an IAE of 21.59. In terms of the results obtained with the cross correlation, the best performance was achieved with the PID tuner and the Stark method.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i6.pp6340-6348</dc:identifier><dc:identifier>10.11591/ijece.v10i6.pp6340-6348</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 6 (2020); 6340</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/21596/14422</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>