Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Power dissipation analysis of PV module under partial shading

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 2 (2021)

DOI
10.11591/ijece.v11i2.pp1029-1035
ISSN
2722-2578, 2088-8708
Terbit
2021-04-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Photovoltaic (PV) generation has been growing dramatically over the last years and it ranges from small, rooftop-mounted or building integrated systems, to large utility scale power stations. Especially for rooftop-mounted PV system, PV modules are serially connected to match with PV inverter input voltage specification. For serially connected PV system, shading is a problem since the shaded PV module reduces the output whole string of PV modules. The excess power from the unshaded PV module is dissipated in the shaded PV module. In this paper, power dissipation of PV module under partial shading is analyzed with circuit analysis for series connected PV modules. The specific current and voltage operating point of the shaded PV module are analyzed under shading. PSIM simulation tool is used to verify the power dissipation analysis. When there is no bypass diode and three solar modules are connected in series, upto 39.1% of the total maximum PV power is dissipated in the shaded PV module. On the other hand, when the bypass is attached, 0.3% of the total maximum power is generated as a loss in the shaded PV module. The proposed analysis technique of shaded PV module could be used in PV system performance analysis, especially for maximum power point tracking (MPPT) performance.

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Kongju National University
  • Korea Institute of Energy Research
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Youngseok JungKorea Institute of Energy Research2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Power dissipation analysis of PV module under partial shading</dc:title><dc:creator>Yu, Byunggyu</dc:creator><dc:creator>Ko, Seok-Cheol</dc:creator><dc:description>&lt;jats:p&gt;Photovoltaic (PV) generation has been growing dramatically over the last years and it ranges from small, rooftop-mounted or building integrated systems, to large utility scale power stations. Especially for rooftop-mounted PV system, PV modules are serially connected to match with PV inverter input voltage specification. For serially connected PV system, shading is a problem since the shaded PV module reduces the output whole string of PV modules. The excess power from the unshaded PV module is dissipated in the shaded PV module.  In this paper, power dissipation of PV module under partial shading is analyzed with circuit analysis for series connected PV modules. The specific current and voltage operating point of the shaded PV module are analyzed under shading. PSIM simulation tool is used to verify the power dissipation analysis. When there is no bypass diode and three solar modules are connected in series, upto 39.1% of the total maximum PV power is dissipated in the shaded PV module. On the other hand, when the bypass is attached, 0.3% of the total maximum power is generated as a loss in the shaded PV module.  The proposed analysis technique of shaded PV module could be used in PV system performance analysis, especially for maximum power point tracking (MPPT) performance.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i2.pp1029-1035</dc:identifier><dc:identifier>10.11591/ijece.v11i2.pp1029-1035</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 2 (2021); 1029</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/23859/14626</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>