DC-DC converter with 50 kHz-500 kHz range of switching frequency for passive component volume reduction

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 2 (2021)

DOI
10.11591/ijece.v11i2.pp1114-1122
ISSN
2722-2578, 2088-8708
Published
2021-04-01
Publisher
Institute of Advanced Engineering and Science

Abstract

This paper presents the relationship of switching frequency towards passive components volume of DC-DC boost converter. Principally, the inductor current ripple and capacitor voltage ripple must be considered in order to design the inductor and capacitor, respectively. By increasing the switching frequency, smaller size and volume of passive component can be designed. As the consequences, the switching loss increases during switching transition at turn-ON and turn-OFF conditions. This paper used soft-switching technique to reduce the switching loss at turn-ON condition. The soft-switching technique is realized by adding resonant circuit in DC-DC boost converter. The effectiveness of resonant circuit will be analysed, thus, the efficiency of the converter can be improved. The range of switching frequency considered in the experimental are 50 kHz to 500 kHz. A 100 W prototype has been developed and tested in order to verify the principle. The switching loss experimentally confirm reduced by implementing soft-switching technique with efficiency converter improved from 96.36% to 97.12% when 500 kHz of switching frequency is considered. The passive components volume reduction is achieved when high switching frequency is used where the total volume of passive component when 50 kHz and 500 kHz are 0.083 dm3 and 0.010 dm3, respectively.

Collaboration network of the authors

11 authors · 30 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Tun Hussein Onn University of Malaysia
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Rosli OmarTun Hussein Onn University of Malaysia1
Che Ku Nor Azie Hailma Che Ku MelorTun Hussein Onn University of Malaysia1
Ariffuddin JoretTun Hussein Onn University of Malaysia1
Maryanti RazaliTun Hussein Onn University of Malaysia1
Muhammad Suhaimi SulongTun Hussein Onn University of Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>DC-DC converter with 50 kHz-500 kHz range of switching frequency for passive component volume reduction</dc:title><dc:creator>Kasiran, Mohd Amirul Naim</dc:creator><dc:creator>Ponniran, Asmarashid</dc:creator><dc:creator>Siam, Nurul Nabilah Mad</dc:creator><dc:creator>Yatim, Mohd Hafizie</dc:creator><dc:creator>Che Ibrahim, Nor Azmira</dc:creator><dc:creator>Md Yunos, Asmawi</dc:creator><dc:description>&lt;jats:p&gt;This paper presents the relationship of switching frequency towards passive components volume of DC-DC boost converter. Principally, the inductor current ripple and capacitor voltage ripple must be considered in order to design the inductor and capacitor, respectively. By increasing the switching frequency, smaller size and volume of passive component can be designed. As the consequences, the switching loss increases during switching transition at turn-ON and turn-OFF conditions. This paper used soft-switching technique to reduce the switching loss at turn-ON condition. The soft-switching technique is realized by adding resonant circuit in DC-DC boost converter. The effectiveness of resonant circuit will be analysed, thus, the efficiency of the converter can be improved. The range of switching frequency considered in the experimental are 50 kHz to 500 kHz. A 100 W prototype has been developed and tested in order to verify the principle. The switching loss experimentally confirm reduced by implementing soft-switching technique with efficiency converter improved from 96.36% to 97.12% when 500 kHz of switching frequency is considered. The passive components volume reduction is achieved when high switching frequency is used where the total volume of passive component when 50 kHz and 500 kHz are 0.083 dm3 and 0.010 dm3, respectively.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i2.pp1114-1122</dc:identifier><dc:identifier>10.11591/ijece.v11i2.pp1114-1122</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 2 (2021); 1114</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/22108/14637</dc:relation></oai_dc:dc>