Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Hybrid energy storage system control analogous to power quality enhancement operation of interlinking converters

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 2 (2021)

DOI
10.11591/ijece.v11i2.pp909-918
ISSN
2722-2578, 2088-8708
Published
2021-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Increasing nonlinear loads and power electronic converters lead to various power quality issues in microgrids (MGs). The interlinking converters (ILCs) can participate in these systems to harmonic control and power quality enhancement. However, ILC participation deteriorates the dc link voltage, system stability, and storage lifetime due to oscillatory current phenomena. To address these problems, a new control strategy for a hybrid energy storage system (HESS) is proposed to eliminate the adverse effects of the harmonic control operation of ILC. Specifically, battery and super-capacitor (SC) are used as HESSs that provide low and high power frequency load, respectively. The proposed strategy tries to compensate the current oscillation imposed by ILC with fuzzy control of HESS. In this method, a proportional-resonant (PR) controller integrated with harmonic compensator (HC) is employed to control the ILC for power quality enhancement and oscillatory current elimination. The main advantages of the proposed strategy are to reduce DGs power fluctuations, precise DC bus voltage regulation for generation and load disturbances, improved grid power quality under nonlinear load and transition conditions. The performance of the proposed method for isolated and grid-connected modes is verified using simulation studies in the MATLAB software environment.

Collaboration network of the authors

3 authors · 3 co-authorship links · 2 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Shahid Beheshti University
  • University of Tehran
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Hybrid energy storage system control analogous to power quality enhancement operation of interlinking converters</dc:title><dc:creator>Hajiaghasi, Salman</dc:creator><dc:creator>Salemnia, Ahmad</dc:creator><dc:creator>Hamzeh, Mohsen</dc:creator><dc:description>&lt;jats:p&gt;Increasing nonlinear loads and power electronic converters lead to various power quality issues in microgrids (MGs). The interlinking converters (ILCs) can participate in these systems to harmonic control and power quality enhancement. However, ILC participation deteriorates the dc link voltage, system stability, and storage lifetime due to oscillatory current phenomena. To address these problems, a new control strategy for a hybrid energy storage system (HESS) is proposed to eliminate the adverse effects of the harmonic control operation of ILC. Specifically, battery and super-capacitor (SC) are used as HESSs that provide low and high power frequency load, respectively. The proposed strategy tries to compensate the current oscillation imposed by ILC with fuzzy control of HESS. In this method, a proportional-resonant (PR) controller integrated with harmonic compensator (HC) is employed to control the ILC for power quality enhancement and oscillatory current elimination. The main advantages of the proposed strategy are to reduce DGs power fluctuations, precise DC bus voltage regulation for generation and load disturbances, improved grid power quality under nonlinear load and transition conditions. The performance of the proposed method for isolated and grid-connected modes is verified using simulation studies in the MATLAB software environment.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i2.pp909-918</dc:identifier><dc:identifier>10.11591/ijece.v11i2.pp909-918</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 2 (2021); 909</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/20400/14708</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>