Melola Discovery

← Melola Discovery

Jurnal SINTA 1

A mho type phase comparator relay guideline using phase comparison technique for a power system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 2 (2021)

DOI
10.11591/ijece.v11i2.pp929-944
ISSN
2722-2578, 2088-8708
Published
2021-04-01
Publisher
Institute of Advanced Engineering and Science

Abstract

This paper presents a mho distance relay simulation based on the phase comparison technique using a typical electrical power systems analysis software for two cases: when the operation state is close to the static voltage limit and during a dynamic perturbation in the system. The paper evaluates the impedance variations caused by complex voltage values, the mho polarization, and the comparator operating region into the complex plane. In addition, the paper found the information for the dynamic perturbations from the outputs considering a mid-term stability program. The simulation of the mho-phase comparator in the static voltage proximity limit detects unit distance elements with impedance measured close to reach the threshold in the steady-state. Dynamic mho simulations in the complex plane are successfully tested by plotting time phase difference curves on the comparator input signals. Relay programmers can use these curves to analyze other phase comparators applications and the corresponding models in the complex plane.

Collaboration network of the authors

18 authors · 53 co-authorship links · 33 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Cienfuegos
  • Universidad de la Costa
  • Universidad Simón Bolívar
  • Universidad Autónoma de Occidente
  • Universidad Pontificia Bolivariana
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Jose Antonio GonzálezUniversity of Cienfuegos4
Marino Godoy ArciaUniversity of Cienfuegos4
José Antonio Gonzalez Cueto CruzUniversity of Cienfuegos4
Vladimir Sousa SantosUniversidad de la Costa1
Enrique Ciro QuispeUniversidad Autónoma de Occidente1
Percy R. ViegoUniversity of Cienfuegos1
Julio Rafael Gómez SarduyUniversity of Cienfuegos1
Jean Carlos Calvo CervantesAffiliation unknown1
Eliab de Jesus Rodriguez AcostaUniversidad de la Costa1
Idi A. IsaacUniversidad Pontificia Bolivariana1
Juan Rivera-AlvaradoUniversidad Simón Bolívar1
Kelly Margarita Berdugo SarmientoUniversidad de la Costa1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A mho type phase comparator relay guideline using phase comparison technique for a power system</dc:title><dc:creator>González-Cueto, José Antonio</dc:creator><dc:creator>Sánchez, Zaid García</dc:creator><dc:creator>Sánchez, Gustavo Crespo</dc:creator><dc:creator>Hernandez, Hernan</dc:creator><dc:creator>Silva Ortega, Jorge Iván</dc:creator><dc:creator>Martínez Díaz, Vicente Leonel</dc:creator><dc:description>&lt;jats:p&gt;This paper presents a mho distance relay simulation based on the phase comparison technique using a typical electrical power systems analysis software for two cases: when the operation state is close to the static voltage limit and during a dynamic perturbation in the system. The paper evaluates the impedance variations caused by complex voltage values, the mho polarization, and the comparator operating region into the complex plane. In addition, the paper found the information for the dynamic perturbations from the outputs considering a mid-term stability program. The simulation of the mho-phase comparator in the static voltage proximity limit detects unit distance elements with impedance measured close to reach the threshold in the steady-state. Dynamic mho simulations in the complex plane are successfully tested by plotting time phase difference curves on the comparator input signals. Relay programmers can use these curves to analyze other phase comparators applications and the corresponding models in the complex plane.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i2.pp929-944</dc:identifier><dc:identifier>10.11591/ijece.v11i2.pp929-944</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 2 (2021); 929</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/21406/14616</dc:relation></oai_dc:dc>