Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Design of type-1 servo controller for grid voltage modulated direct-power control of single-phase grid-connected PV inverter

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 3 (2021)

DOI
10.11591/ijece.v11i3.pp1912-1923
ISSN
2722-2578, 2088-8708
Published
2021-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents direct control of active and reactive power using grid voltage modulation for single-phase grid-connected photovoltaic inverter. A design of type-1 servo system based on pole-placement method is proposed to control the power flow using a simplified multiple-input multiple-output (MIMO) model of the system. Phase-locked loop (PLL) with a quarter cycle time delay is used to estimate the grid phase angle for the purpose of performing the stationary and synchronous reference frame transformation. Unipolar pulse width modulation (PWM) technique is used to control a single-phase inverter with 2.7 KVA capacity connected to the photovoltaic system. The proposed controller can simply be tuned using minimum number of controller gains to achieve the transient and steady-state performance requirements. The proposed system, was capable of operating for a wide range of solar irradiance levels with a power factor in the range of 0.95 (leading/lagging), for the reactive power compensation purposes.

Collaboration network of the authors

12 authors · 23 co-authorship links · 10 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Applied Science Private University
  • Heriot-Watt University
  • Ohio Northern University
  • Al Ain University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Yazeed Yasin GhadiAl Ain University5
Emad A. AwadaApplied Science Private University2
Khalil SalihApplied Science Private University2
Yazed Yasin GhadiAffiliation unknown1
Ayman Abu BakerAffiliation unknown1
Abdelrahman RadwanApplied Science Private University1
Nasser AbdellatifApplied Science Private University1
Maryam AkhozahiehApplied Science Private University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Design of type-1 servo controller for grid voltage modulated direct-power control of single-phase grid-connected PV inverter</dc:title><dc:creator>Radwan, Eyad</dc:creator><dc:creator>Nour, Mutasim</dc:creator><dc:creator>Baniyounes, Ali</dc:creator><dc:creator>Al Olimat, Khalid S.</dc:creator><dc:description>&lt;jats:p&gt;This paper presents direct control of active and reactive power using grid voltage modulation for single-phase grid-connected photovoltaic inverter. A design of type-1 servo system based on pole-placement method is proposed to control the power flow using a simplified multiple-input multiple-output (MIMO) model of the system. Phase-locked loop (PLL) with a quarter cycle time delay is used to estimate the grid phase angle for the purpose of performing the stationary and synchronous reference frame transformation. Unipolar pulse width modulation (PWM) technique is used to control a single-phase inverter with 2.7 KVA capacity connected to the photovoltaic system. The proposed controller can simply be tuned using minimum number of controller gains to achieve the transient and steady-state performance requirements. The proposed system, was capable of operating for a wide range of solar irradiance levels with a power factor in the range of 0.95 (leading/lagging), for the reactive power compensation purposes.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i3.pp1912-1923</dc:identifier><dc:identifier>10.11591/ijece.v11i3.pp1912-1923</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 3 (2021); 1912</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/23793/14736</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>