Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Feasibility of using photovoltaic solar energy for water treatment plants

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 3 (2021)

DOI
10.11591/ijece.v11i3.pp1962-1968
ISSN
2722-2578, 2088-8708
Published
2021-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The purpose of this research is to determine the feasibility of supplying photovoltaic solar energy for the electrical requirements of drinking water and wastewater treatment plants, in six regions of Colombia, with different geographic and climatological conditions: Andean Region, Amazon Region, Orinoquía Region, Caribbean Region, Pacific Region, and Insular Region. The study revealed that the costs of the photovoltaic systems oscillate between USD 32,486.86 and USD 40,716.86, without using a storage system with batteries, since the price of these makes the investment recovery unfeasible. Instead of using batteries to store energy, a water storage system is used. The total daily load of the sanitation systems is 57 kWh/day, which would avoid 7120.44 kgCO2 per year. Besides, during the entire useful life of the 20-year project, 142.4 tCO2 would not be released into the environment.

Collaboration network of the authors

14 authors · 38 co-authorship links · 25 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad de Bogotá Jorge Tadeo Lozano
  • Universidad Nacional de Colombia
  • Universidad del Rosario
  • University of Stuttgart
  • Universitat Politècnica de València
  • Universidad Tecnológica del Chocó Diego Luis Córdoba
  • University of Oklahoma
  • Other organisations
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Isaac DynerUniversidad de Bogotá Jorge Tadeo Lozano4
Daniel OspinaUniversidad de Bogotá Jorge Tadeo Lozano3
Nicolas EscalanteUniversity of Stuttgart3
Edison BangueroUniversitat Politècnica de València1
Héctor D. AgudeloUniversidad Tecnológica del Chocó Diego Luis Córdoba1
Daniel Hernán Ospina BarragánUniversity of Oklahoma1
Diego Alberto CarreñoUniversidad de Bogotá Jorge Tadeo Lozano1
Enrique Ángel SanintUniversidad EIA1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Feasibility of using photovoltaic solar energy for water treatment plants</dc:title><dc:creator>Saavedra, Alexander</dc:creator><dc:creator>Galvis, Nataly Alejandra</dc:creator><dc:creator>Castaneda, Mónica</dc:creator><dc:creator>Zapata, Sebastian</dc:creator><dc:creator>Mesa, Fredy</dc:creator><dc:creator>Aristizábal, Andrés Julián</dc:creator><dc:description>&lt;jats:p&gt;The purpose of this research is to determine the feasibility of supplying photovoltaic solar energy for the electrical requirements of drinking water and wastewater treatment plants, in six regions of Colombia, with different geographic and climatological conditions: Andean Region, Amazon Region, Orinoquía Region, Caribbean Region, Pacific Region, and Insular Region. The study revealed that the costs of the photovoltaic systems oscillate between USD 32,486.86 and USD 40,716.86, without using a storage system with batteries, since the price of these makes the investment recovery unfeasible. Instead of using batteries to store energy, a water storage system is used. The total daily load of the sanitation systems is 57 kWh/day, which would avoid 7120.44 kgCO2 per year. Besides, during the entire useful life of the 20-year project, 142.4 tCO2 would not be released into the environment.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i3.pp1962-1968</dc:identifier><dc:identifier>10.11591/ijece.v11i3.pp1962-1968</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 3 (2021); 1962</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/23967/14830</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>