Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Numerical analysis of the photovoltaic system inspection with active cooling

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 4 (2021)

DOI
10.11591/ijece.v11i4.pp2779-2789
ISSN
2722-2578, 2088-8708
Published
2021-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The use of solar energy may replace the present fossil fuel or gas to produce electricity. The goal of this study is to set up a simulation model to survey the performance of a photovoltaic thermal system (PV/T) based on the computational fluid dynamics (CFD) method. Ansys fluent software has been used for the simulation procedure. The electrical panel output and its efficiency were investigated numerically. In addition, the effect of variations in absorbed radiation on inlet fluid and absorber panel temperature on the system performance was investigated. The study was conducted for three cases, in a first case, where there is no refrigerant in the system and in the latter case, at constant fluid rate of the pump, whereas the third case with optimal pump operation. The numerical findings obtained from CFD simulators have been compared with the test records of the experimental results of the literature. The two results have a good agreement. From the obtained results, it can be noted that the system shows a good improvement for the electric net efficiency level of 3.52% with a lower reduction of the thermal system efficiency of 1.96% in comparison to the system when using the constantly high flow rate.

Collaboration network of the authors

7 authors · 11 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Tikrit
  • Northern Technical University
  • National University of Malaysia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mohammed Ayad SaadNational University of Malaysia2
Ali Hlal MutlaqAffiliation unknown2
Khaleel Ali KhudhurNorthern Technical University1
Nabeel Mohammed Akram SamadNorthern Technical University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Numerical analysis of the photovoltaic system inspection with active cooling</dc:title><dc:creator>Mohammed, Ahmed Hasan</dc:creator><dc:creator>Hasan, Ghanim Thiab</dc:creator><dc:creator>Ali, Kamil Jadu</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;The use of solar energy may replace the present fossil fuel or gas to produce electricity. The goal of this study is to set up a simulation model to survey the performance of a photovoltaic thermal system (PV/T) based on the computational fluid dynamics (CFD) method. Ansys fluent software has been used for the simulation procedure. The electrical panel output and its efficiency were investigated numerically. In addition, the effect of variations in absorbed radiation on inlet fluid and absorber panel temperature on the system performance was investigated. The study was conducted for three cases, in a first case, where there is no refrigerant in the system and in the latter case, at constant fluid rate of the pump, whereas the third case with optimal pump operation. The numerical findings obtained from CFD simulators have been compared with the test records of the experimental results of the literature. The two results have a good agreement. From the obtained results, it can be noted that the system shows a good improvement for the electric net efficiency level of 3.52% with a lower reduction of the thermal system efficiency of 1.96% in comparison to the system when using the constantly high flow rate.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i4.pp2779-2789</dc:identifier><dc:identifier>10.11591/ijece.v11i4.pp2779-2789</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 4 (2021); 2779</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/23142/14878</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>