Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Breast cancer diagnosis system using hybrid support vector machine-artificial neural network

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 4 (2021)

DOI
10.11591/ijece.v11i4.pp3059-3069
ISSN
2722-2578, 2088-8708
Published
2021-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Breast cancer is the second most common cancer occurring in women. Early detection through mammogram screening can save more women’s lives. However, even senior radiologists may over-diagnose the clinical condition. Machine learning (ML) is the most used technique in the diagnosis of cancer to help reduce human errors. This study is aimed to develop a computer-aided detection (CAD) system using ML for classification purposes. In this work, 80 digital mammograms of normal breasts, 40 of benign and 40 of malignant cases were chosen from the mini MIAS dataset. These images were denoised using median filter after they were segmented to obtain a region of interest (ROI) and enhanced using histogram equalization. This work compared the performance of artificial neural network (ANN), support vector machine (SVM), reduced features of SVM and the hybrid SVM-ANN for classification process using the statistical and gray level co-occurrence matrix (GLCM) features extracted from the enhanced images. It is found that the hybrid SVM-ANN gives the best accuracy of 99.4% and 100% in differentiating normal from abnormal, and benign from malignant cases, respectively. This hybrid SVM-ANN model was deployed in developing the CAD system which showed relatively good accuracy of 98%.

Collaboration network of the authors

8 authors · 14 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Tun Hussein Onn University of Malaysia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Sanjoy Kumar DebnathTun Hussein Onn University of Malaysia2
Susama BagchiTun Hussein Onn University of Malaysia2
Mars Hong Xuan WaiTun Hussein Onn University of Malaysia1
Xavier NguAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Breast cancer diagnosis system using hybrid support vector machine-artificial neural network</dc:title><dc:creator>Lim, Tze Sheng</dc:creator><dc:creator>Tay, Kim Gaik</dc:creator><dc:creator>Huong, Audrey</dc:creator><dc:creator>Lim, Xiang Yang</dc:creator><dc:description>&lt;jats:p&gt;Breast cancer is the second most common cancer occurring in women. Early detection through mammogram screening can save more women’s lives. However, even senior radiologists may over-diagnose the clinical condition. Machine learning (ML) is the most used technique in the diagnosis of cancer to help reduce human errors. This study is aimed to develop a computer-aided detection (CAD) system using ML for classification purposes. In this work, 80 digital mammograms of normal breasts, 40 of benign and 40 of malignant cases were chosen from the mini MIAS dataset. These images were denoised using median filter after they were segmented to obtain a region of interest (ROI) and enhanced using histogram equalization. This work compared the performance of artificial neural network (ANN), support vector machine (SVM), reduced features of SVM and the hybrid SVM-ANN for classification process using the statistical and gray level co-occurrence matrix (GLCM) features extracted from the enhanced images. It is found that the hybrid SVM-ANN gives the best accuracy of 99.4% and 100% in differentiating normal from abnormal, and benign from malignant cases, respectively. This hybrid SVM-ANN model was deployed in developing the CAD system which showed relatively good accuracy of 98%.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i4.pp3059-3069</dc:identifier><dc:identifier>10.11591/ijece.v11i4.pp3059-3069</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 4 (2021); 3059</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/24584/14911</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>