Jurnal
A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant
Rekayasa · Vol. 22 No. 2 (2024) · hlm. 84–96
ISSN 2527-6964, 0216-6631
Terbit 2024-12-31
Penerbit Universitas Negeri Semarang
Bahasa eng
Abstrak
Biogas as one of the renewable energy sources contains hydrogen sulfide (H₂S) which causes equipment corrosion and gives negative impacts on the environment. To study some factors that affect the H2S removal efficiency, evaluation was done on the performance of existing H2S scrubber. For the case study, it was found that the existing scrubber performance did not reach the target (< 200 ppm-v H2S) with 1,450 Nm3 biogas/h and 2,550 ppm-v H2S inlet (-10 mbarg and 35oC). Scenarios were made by varying the design parameters of the H2S outlet scrubber (0 - 1,140 ppm-v), H2S inlet scrubber (2,550 and 3,000 ppm-v), and biogas flow (1,450 and 1,700 Nm3 biogas/h). Based on the analysis results, it was found that the initial design had already considered an overdesign factor of at least 52 times. Through solubility and residence time analysis, favorable scrubber operation is to run at low liquid spray flow (~ 70 m3/h). In addition, low flow liquid spray could help activate the bacteria on the bio-packing media surfaces so that they are not eroded by the high erosive spray velocity. This study’s results are expected to be a reference for the biogas industry in evaluating the performance of H2S scrubbers.
Jaringan kolaborasi para penulis
15 penulis ·
40 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
State University of Semarang Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/rekayasa/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant</dc:title>
<dc:creator xml:lang="en">Akbar, Ramavi</dc:creator>
<dc:creator xml:lang="en">Hanif Ardhiansyah</dc:creator>
<dc:creator xml:lang="en">Muhammad Wasim Ikram</dc:creator>
<dc:subject xml:lang="en">hydrogen sulfide (H₂S)</dc:subject>
<dc:subject xml:lang="en">biogas</dc:subject>
<dc:subject xml:lang="en">scrubber</dc:subject>
<dc:subject xml:lang="en">performance evaluation</dc:subject>
<dc:subject xml:lang="en">solubility</dc:subject>
<dc:subject xml:lang="en">residence time</dc:subject>
<dc:description xml:lang="en">Biogas as one of the renewable energy sources contains hydrogen sulfide (H₂S) which causes equipment corrosion and gives negative impacts on the environment. To study some factors that affect the H2S removal efficiency, evaluation was done on the performance of existing H2S scrubber. For the case study, it was found that the existing scrubber performance did not reach the target (&lt; 200 ppm-v H2S) with 1,450 Nm3 biogas/h and 2,550 ppm-v H2S inlet (-10 mbarg and 35oC). Scenarios were made by varying the design parameters of the H2S outlet scrubber (0 - 1,140 ppm-v), H2S inlet scrubber (2,550 and 3,000 ppm-v), and biogas flow (1,450 and 1,700 Nm3 biogas/h). Based on the analysis results, it was found that the initial design had already considered an overdesign factor of at least 52 times. Through solubility and residence time analysis, favorable scrubber operation is to run at low liquid spray flow (~ 70 m3/h). In addition, low flow liquid spray could help activate the bacteria on the bio-packing media surfaces so that they are not eroded by the high erosive spray velocity. This study’s results are expected to be a reference for the biogas industry in evaluating the performance of H2S scrubbers.</dc:description>
<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
<dc:date>2024-12-31</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.unnes.ac.id/journals/rekayasa/article/view/30454</dc:identifier>
<dc:identifier>10.15294/rekayasa.v22i2.30454</dc:identifier>
<dc:source xml:lang="en">Rekayasa; Vol. 22 No. 2 (2024); 84-96</dc:source>
<dc:source>2527-6964</dc:source>
<dc:source>0216-6631</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.unnes.ac.id/journals/rekayasa/article/view/30454/4970</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2024 Rekayasa : Jurnal Penerapan Teknologi dan Pembelajaran</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Akbar, R., Ardhiansyah, H., & Ikram, M. W. (2024). A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant. Rekayasa, 22(2), 84–96. https://doi.org/10.15294/rekayasa.v22i2.30454
Salin
IEEE
R. Akbar, H. Ardhiansyah, and M. W. Ikram, “A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant,” Rekayasa, vol. 22, no. 2, pp. 84–96, 2024, doi: 10.15294/rekayasa.v22i2.30454.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.