Melola Discovery

← Melola Discovery

Jurnal

Cr(VI) Removal Using A Dual Chamber Microbial Fuel Cell

Sainteknol : Jurnal Sains dan Teknologi · Vol. 22 No. 1 (2024) · hlm. 22–34

DOI
10.15294/sainteknol.v22i1.7752
ISSN
2527-3604, 0216-4566
Terbit
2024-06-23
Penerbit
Universitas Negeri Semarang
Bahasa
eng

Abstrak

Chromium ions is notably a hazardous heavy metal due to its toxic and carcinogenic nature, particularly in its hexavalent form, Cr(VI). One of the major Cr(VI) pollution source is from electroplating industry effluent, which may contain high concentrations that pose a risk of contamination of aquatic and soil ecosystems if not treated carefully. One of the alternative method known to be able to treat Cr(VI) wastewater is by using microbial fuel cell (MFC). This research focused on on the removal of Cr(VI) from synthetic electroplating wastewater using a 4L dual-chamber MFC under fed-batch condition, as well as investigating the impact of mixed liquor suspended solids (MLSS) and chemical oxygen demand (COD) concentrations to its performance. Observed parameters include the efficiency of Cr(VI) removal and power density. Septage sludge and acetate were both used as biomass and substrate source respectively. Based on this research, it can be concluded that the highest Cr(VI) removal efficiency and power density were achieved using specific MLSS and COD concentration that resulting in F/M ratio of 0,459 to 0,489 gCOD/gMLSS. From initial Cr(VI) concentration of 50 mg/L, the highest removal was obtained by MFC running with initial MLSS and COD concentrations of 3.500 and 1.500 mg/L respectively, achieving 62,17% over 312 hours. This setup also produced the highest power density of 48,22 mW/m².

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 16 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • University of Technology Malaysia
  • University of Yamanashi
  • Indonesia University of Education
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Topik HidayatIndonesia University of Education1
Tony HadibrataAfiliasi tidak diketahui1
Risky Ayu KristantiUniversity of Yamanashi1
Abdull Rahim Mohd YusoffAfiliasi tidak diketahui1
Azmi ArisUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/sainteknol/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Cr(VI) Removal Using A Dual Chamber Microbial Fuel Cell</dc:title>
	<dc:creator xml:lang="en">Ferdinand, Julian</dc:creator>
	<dc:creator xml:lang="en">Yuniarto, Adhi</dc:creator>
	<dc:subject xml:lang="en">Dual Chamber; Microbial Fuel Cell; Power Density; Septage Sludge </dc:subject>
	<dc:description xml:lang="en">Chromium ions is notably a hazardous heavy metal due to its toxic and carcinogenic nature, particularly in its hexavalent form, Cr(VI). One of the major Cr(VI) pollution source is from electroplating industry effluent, which may contain high concentrations that pose a risk of contamination of aquatic and soil ecosystems if not treated carefully. One of the alternative method known to be able to treat Cr(VI) wastewater is by using microbial fuel cell (MFC). This research focused on on the removal of Cr(VI) from synthetic electroplating wastewater using a 4L dual-chamber MFC under fed-batch condition, as well as investigating the impact of mixed liquor suspended solids (MLSS) and chemical oxygen demand (COD) concentrations to its performance. Observed parameters include the efficiency of Cr(VI) removal and power density. Septage sludge and acetate were both used as biomass and substrate source respectively. Based on this research, it can be concluded that the highest Cr(VI) removal efficiency and power density were achieved using specific MLSS and COD concentration that resulting in F/M ratio of 0,459 to 0,489 gCOD/gMLSS. From initial Cr(VI) concentration of 50 mg/L, the highest removal was obtained by MFC running with initial MLSS and COD concentrations of 3.500 and 1.500 mg/L respectively, achieving 62,17% over 312 hours. This setup also produced the highest power density of 48,22 mW/m².</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
	<dc:date>2024-06-23</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/sainteknol/article/view/7752</dc:identifier>
	<dc:identifier>10.15294/sainteknol.v22i1.7752</dc:identifier>
	<dc:source xml:lang="en">Sainteknol : Jurnal Sains dan Teknologi; Vol. 22 No. 1 (2024): June 2024; 22-34</dc:source>
	<dc:source>2527-3604</dc:source>
	<dc:source>0216-4566</dc:source>
	<dc:source>10.15294/sainteknol.v22i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/sainteknol/article/view/7752/1074</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Sainteknol : Jurnal Sains dan Teknologi</dc:rights>
</oai_dc:dc>