A hybrid deep learning approach towards building an intelligent system for pneumonia detection in chest X-ray images

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 6 (2021)

DOI
10.11591/ijece.v11i6.pp5530-5540
ISSN
2722-2578, 2088-8708
Published
2021-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Pneumonia is a major cause for the death of children. In order to overcome the subjectivity and time consumption of the traditional detection of pneumonia from chest X-ray images; this work hypothesized that a hybrid deep learning system that consists of a convolutional neural network (CNN) model with another type of classifiers will improve the performance of the detection system. Three types of classifiers (support vector machine (SVM), k-nearest neighbor (KNN), and random forest (RF) were used along with the traditional CNN classification system (Softmax) to automatically detect pneumonia from chest X-ray images. The performance of the hybrid systems was comparable to that of the traditional CNN model with Softmax in terms of accuracy, precision, and specificity; except for the RF hybrid system which had less performance than the others. On the other hand, KNN hybrid system had the best consumption time, followed by the SVM, Softmax, and lastly the RF system. However, this improvement in consumption time (up to 4 folds) was in the expense of the sensitivity. A new hybrid artificial intelligence methodology for pneumonia detection has been implemented using small-sized chest X-ray images. The novel system achieved a very efficient performance with a short classification consumption time.

Collaboration network of the authors

10 authors · 27 co-authorship links · 6 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Yarmouk University
  • Jordan University of Science and Technology
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Isam F. Abu-QasmiehYarmouk University2
Hiam AlquranYarmouk University2
Mohammed AlslityYarmouk University1
Khaled Zayed Ali AlawnehJordan University of Science and Technology1
Ahmed Al-RasheedYarmouk University1
Mohammed Al-HawariYarmouk University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A hybrid deep learning approach towards building an intelligent system for pneumonia detection in chest X-ray images</dc:title><dc:creator>S. Masad, Ihssan</dc:creator><dc:creator>Alqudah, Amin</dc:creator><dc:creator>Alqudah, Ali Mohammad</dc:creator><dc:creator>Almashaqbeh, Sami</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;Pneumonia is a major cause for the death of children. In order to overcome the subjectivity and time consumption of the traditional detection of pneumonia from chest X-ray images; this work hypothesized that a hybrid deep learning system that consists of a convolutional neural network (CNN) model with another type of classifiers will improve the performance of the detection system. Three types of classifiers (support vector machine (SVM), k-nearest neighbor (KNN), and random forest (RF) were used along with the traditional CNN classification system (Softmax) to automatically detect pneumonia from chest X-ray images. The performance of the hybrid systems was comparable to that of the traditional CNN model with Softmax in terms of accuracy, precision, and specificity; except for the RF hybrid system which had less performance than the others. On the other hand, KNN hybrid system had the best consumption time, followed by the SVM, Softmax, and lastly the RF system. However, this improvement in consumption time (up to 4 folds) was in the expense of the sensitivity. A new hybrid artificial intelligence methodology for pneumonia detection has been implemented using small-sized chest X-ray images. The novel system achieved a very efficient performance with a short classification consumption time.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i6.pp5530-5540</dc:identifier><dc:identifier>10.11591/ijece.v11i6.pp5530-5540</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 6 (2021); 5530</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/25649/15270</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>