Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

A global system for mobile communications-based electrical power consumption for a non-contact smart billing system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 6 (2021)

DOI
10.11591/ijece.v11i6.pp4659-4666
ISSN
2722-2578, 2088-8708
Published
2021-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper proposes a cheap solution to be a starting point for building smart electrical power billing systems. Electrical power has many challenges issues in Iraq, one of these challenges and the most important is the Billing system. The smart power meter uses an Arduino Uno as the core for controlling the sensed data and transmits it to the electrical power unit for billing services. The system is constructed with two parts: the transmitting unit measures the current, voltage, power and power factor through the compact new sensor PZEM-004T. The data sensed and processed by the microcontroller which displayed the KWh on (2*16 LCD) display. This data also transmitted to the electrical power company unit via the global system for mobile communications (GSM) module (SIM900A) which is a dual band GSM/GPRS- general packet radio service modem. The receiving part is mainly dedicated for collecting the required consumed power data via the same (SIM900A) module and also can display it using (2*16 LCD) display. For the sake of saving these data, the receiver part uses SD ram for such purposes. With such proposed system the electrical power company can control and collect their fees monthly without loss and with minimum cost.

Collaboration network of the authors

10 authors · 17 co-authorship links · 5 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Middle Technical University
  • University of Information Technology and Communications
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Faeza Abbas AbedMiddle Technical University2
Falah Hasan MahdiMiddle Technical University2
kareem Ghazi AbdulhusseinMiddle Technical University1
Naseer M. YasinMiddle Technical University1
Jaafar A. AldhaibaniUniversity of Information Technology and Communications1
Yaseen Naser JurnUniversity of Information Technology and Communications1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A global system for mobile communications-based electrical power consumption for a non-contact smart billing system</dc:title><dc:creator>Hasan, Ihsan Jabbar</dc:creator><dc:creator>Waheib, Bushra Mahmoud</dc:creator><dc:creator>Jalil Salih, Nahla Abdul</dc:creator><dc:creator>Abdulkhaleq, Nadhir Ibrahim</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;This paper proposes a cheap solution to be a starting point for building smart electrical power billing systems. Electrical power has many challenges issues in Iraq, one of these challenges and the most important is the Billing system. The smart power meter uses an Arduino Uno as the core for controlling the sensed data and transmits it to the electrical power unit for billing services. The system is constructed with two parts: the transmitting unit measures the current, voltage, power and power factor through the compact new sensor PZEM-004T. The data sensed and processed by the microcontroller which displayed the KWh on (2*16 LCD) display. This data also transmitted to the electrical power company unit via the global system for mobile communications (GSM) module (SIM900A) which is a dual band GSM/GPRS-&amp;lt;/span&amp;gt;&amp;lt;span&amp;gt;general packet radio service&amp;lt;/span&amp;gt;&amp;lt;span&amp;gt; modem. The receiving part is mainly dedicated for collecting the required consumed power data via the same (SIM900A) module and also can display it using (2*16 LCD) display. For the sake of saving these data, the receiver part uses SD ram for such purposes. With such proposed system the electrical power company can control and collect their fees monthly without loss and with minimum cost.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i6.pp4659-4666</dc:identifier><dc:identifier>10.11591/ijece.v11i6.pp4659-4666</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 6 (2021); 4659</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/24347/15163</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>