Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Overall fuzzy logic control strategy of direct driven PMSG wind turbine connected to grid

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 6 (2021)

DOI
10.11591/ijece.v11i6.pp5515-5529
ISSN
2722-2578, 2088-8708
Published
2021-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The fuzzy logic strategies reported in the literature about the control of direct drive permanent magnet synchronous generator (PMSG) connected to grid are limited in terms of inclusiveness and efficiency. So an overall control based on fuzzy logic and anti-windup compensation is proposed in this paper. Aiming at the inadequate of hill climb search (HCS) MPPT with fixed step size, the fuzzy logic is introduced in the stage of "generating rotor speed reference" to overcome the oscillations and slowness in traditional method. PI controllers are replaced by anti-windup fuzzy logic controllers in the "machine side control" stage and in "grid side control" stage to pertinently regulate the reference parameters. Then comparison tests with classical methods are implemented under varying climatic conditions. The results obtained demonstrate that the developed control is superior to other methods in response time (less than 4.528E-04 s), precision (an overshoot about 0.41%) and quality of produced energy (efficiency is 91%). The study verifying the feasibility and effectiveness of this algorithm in PMSG wind turbine connected to grid.

Collaboration network of the authors

12 authors · 32 co-authorship links · 15 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Mohamed I University
  • Université Ibn Zohr
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Institut of Research in Solar Energy and New Energies
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mohammed EL FahssiMohamed I University2
Taoufik OuchbelMohamed I University2
Mustapha KourchiUniversité Ibn Zohr1
Mohamed AjaamoumUniversité Ibn Zohr1
Samia JenkalUniversité Ibn Zohr1
Driss YousfiUniversiti Malaysia Pahang Al-Sultan Abdullah1
Ahmed BenlarabiInstitut of Research in Solar Energy and New Energies1
Mhand OubellaUniversité Ibn Zohr1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Overall fuzzy logic control strategy of direct driven PMSG wind turbine connected to grid</dc:title><dc:creator>Fannakh, Mhamed</dc:creator><dc:creator>Larbi Elhafyani, Mohamed</dc:creator><dc:creator>Zouggar, Smail</dc:creator><dc:creator>Zahboune, Hassan</dc:creator><dc:description>&lt;jats:p&gt;The fuzzy logic strategies reported in the literature about the control of direct drive permanent magnet synchronous generator (PMSG) connected to grid are limited in terms of inclusiveness and efficiency. So an overall control based on fuzzy logic and anti-windup compensation is proposed in this paper. Aiming at the inadequate of hill climb search (HCS) MPPT with fixed step size, the fuzzy logic is introduced in the stage of "generating rotor speed reference" to overcome the oscillations and slowness in traditional method. PI controllers are replaced by anti-windup fuzzy logic controllers in the "machine side control" stage and in "grid side control" stage to pertinently regulate the reference parameters. Then comparison tests with classical methods are implemented under varying climatic conditions. The results obtained demonstrate that the developed control is superior to other methods in response time (less than 4.528E-04 s), precision (an overshoot about 0.41%) and quality of produced energy (efficiency is 91%). The study verifying the feasibility and effectiveness of this algorithm in PMSG wind turbine connected to grid.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i6.pp5515-5529</dc:identifier><dc:identifier>10.11591/ijece.v11i6.pp5515-5529</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 6 (2021); 5515</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/25647/15269</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>