Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Study of power management of standalone DC microgrids with battery supercapacitor hybrid energy storage system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 1 (2022)

DOI
10.11591/ijece.v12i1.pp114-121
ISSN
2722-2578, 2088-8708
Published
2022-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In the last years, renewable energy (RE) is increasing widely in the energy sector, and microgrid technology is overgrowing. In this paper, stand-alone microgrid using solar photovoltaic (PV) energy as a source of renewable energy is simulated to provide power for direct current (DC) loads with hybrid energy storage system (HESS) which consists of battery and supercapacitor bank. The proposed microgrid system is tested under various cases of load and variable irradiance to confirm and validate the proposed management strategy to remain the DC bus voltage within a stable limit. The performance of DC microgrid is comparing with and without supercapacitor (SC) bank and notes a desirable decrease in the magnitude of transient voltage when using HESS. The sun power SPR-E19-320 standard was simulated to analyze system performance taking into account the constant load demand. Note that HESS helps reduce transient of DC voltage very effectively in all situations. Very large transients arise due to sudden changes in load demand is also compensated by HESS. The results obtained indicate that the stand-alone DC microgrid with HESS is very beneficial for reducing transient of DC-link voltage that occurs due to sudden change in load or fault. The proposed system is performed by MATLAB/Simulink environment.

Collaboration network of the authors

3 authors · 3 co-authorship links · 2 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Imam Reza International University
  • Al-Furat Al-Awsat Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Study of power management of standalone DC microgrids with battery supercapacitor hybrid energy storage system</dc:title><dc:creator>Seger Al-Salloomee, Ali Gaeed</dc:creator><dc:creator>Khosroabadi, Saeed</dc:creator><dc:creator>Abdullah Albukariat, Ali Abdulabbas</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;In the last years, renewable energy (RE) is increasing widely in the energy sector, and microgrid technology is overgrowing. In this paper, stand-alone microgrid using solar photovoltaic (PV) energy as a source of renewable energy is simulated to provide power for direct current (DC) loads with hybrid energy storage system (HESS) which consists of battery and supercapacitor bank. The proposed microgrid system is tested under various cases of load and variable irradiance to confirm and validate the proposed management strategy to remain the DC bus voltage within a stable limit. The performance of DC microgrid is comparing with and without supercapacitor (SC) bank and notes a desirable decrease in the magnitude of transient voltage when using HESS. The sun power SPR-E19-320 standard was simulated to analyze system performance taking into account the constant load demand. Note that HESS helps reduce transient of DC voltage very effectively in all situations. Very large transients arise due to sudden changes in load demand is also compensated by HESS. The results obtained indicate that the stand-alone DC microgrid with HESS is very beneficial for reducing transient of DC-link voltage that occurs due to sudden change in load or fault. The proposed system is performed by MATLAB/Simulink environment.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i1.pp114-121</dc:identifier><dc:identifier>10.11591/ijece.v12i1.pp114-121</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 1 (2022); 114</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/24371/15298</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>