Improving hemoglobin estimation accuracy through standardizing of light-emitting diode power

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 1 (2022)

DOI
10.11591/ijece.v12i1.pp219-228
ISSN
2722-2578, 2088-8708
Terbit
2022-02-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Nowadays, hemoglobin monitoring is essential during surgeries, blood donations, and dialysis. Which are normally done using invasive methods. To monitor hemoglobin, a non-invasive hemoglobin meter was developed with five fixed light-emitting diode (LED) wavelengths at 670 nm, 770 nm, 810 nm, 850 nm, 950 nm and controlled using an Arduino Uno embedded development board. A photodetector with an on-chip trans-impedance amplifier was utilized to acquire the transmitted signal through the finger using the photoplethysmography (PPG) principle. Before the standardization of LED power, we had tested the designed system on fifteen subjects for the five wavelengths and estimated the hemoglobin with an accuracy of 96.51% and root mean square error (RMSE) of 0.57 gm/dL. To further improve the accuracy, the LED power was standardized and the PPG signal was reacquired on the same subjects. With this, the accuracy improved to 98.29% and also reduced the RMSE to 0.36 gm/dL. The designed system with LED power standardization showed a good agreement with pathology results with the coefficient of determination R 2 =0.981. Also, Bland–Altman analysis was used to evaluate the designed system and it showed good agreement between the two measurements.

Jaringan kolaborasi para penulis

4 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Goa University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Improving hemoglobin estimation accuracy through standardizing of light-emitting diode power</dc:title><dc:creator>Pinto, Caje Francis</dc:creator><dc:creator>Parab, Jivan Shrikrishna</dc:creator><dc:creator>Sequeira, Marlon Darius</dc:creator><dc:creator>Naik, Gourish</dc:creator><dc:description>&lt;jats:p&gt;Nowadays, hemoglobin monitoring is essential during surgeries, blood donations, and dialysis. Which are normally done using invasive methods. To monitor hemoglobin, a non-invasive hemoglobin meter was developed with five fixed light-emitting diode (LED) wavelengths at 670 nm, 770 nm, 810 nm, 850 nm, 950 nm and controlled using an Arduino Uno embedded development board. A photodetector with an on-chip trans-impedance amplifier was utilized to acquire the transmitted signal through the finger using the photoplethysmography (PPG) principle. Before the standardization of LED power, we had tested the designed system on fifteen subjects for the five wavelengths and estimated the hemoglobin with an accuracy of 96.51% and root mean square error (RMSE) of 0.57 gm/dL. To further improve the accuracy, the LED power was standardized and the PPG signal was reacquired on the same subjects. With this, the accuracy improved to 98.29% and also reduced the RMSE to 0.36 gm/dL. The designed system with LED power standardization showed a good agreement with pathology results with the coefficient of determination R&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;=0.981. Also, Bland–Altman analysis was used to evaluate the designed system and it showed good agreement between the two measurements.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i1.pp219-228</dc:identifier><dc:identifier>10.11591/ijece.v12i1.pp219-228</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 1 (2022); 219</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/24360/15309</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>