Abstract

Power transformers are one of the most important and complex parts of an electric power system. Maintenance is performed for this responsible part based on the technical condition of the transformer using a predictive approach. The technical condition of the power transformer can be diagnosed using a range of different diagnostic methods, for example, analysis of dissolved gases (DGA), partial discharge monitoring, vibration monitoring, and moisture monitoring. In this paper, the authors present a digital model for predicting the technical condition of a power transformer and determining the type of defect and its cause in the event of defect detection. The predictive digital model is developed using the programming environment in LabVIEW and is based on the fuzzy logic approach to the DGA method, interpreted by the key gas method and the Dornenburg ratio method. The developed digital model is verified on a set of 110 kV and 220 kV transformers of one of the sections of the distribution network and thermal power plant in the Russian Federation. The results obtained showed its high efficiency in predicting faults and the possibility of using it as an effective computing tool to facilitate the work of the operating personnel of power enterprises.

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Novosibirsk State Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Predicting the technical condition of the power transformer using fuzzy logic and dissolved gas analysis method</dc:title><dc:creator>Levin, Vladimir Mikhailovich</dc:creator><dc:creator>Yahya, Ammar Abdulazez</dc:creator><dc:creator>A. Boyarova, Diana</dc:creator><dc:description>&lt;jats:p&gt;Power transformers are one of the most important and complex parts of an electric power system. Maintenance is performed for this responsible part based on the technical condition of the transformer using a predictive approach. The technical condition of the power transformer can be diagnosed using a range of different diagnostic methods, for example, analysis of dissolved gases (DGA), partial discharge monitoring, vibration monitoring, and moisture monitoring. In this paper, the authors present a digital model for predicting the technical condition of a power transformer and determining the type of defect and its cause in the event of defect detection. The predictive digital model is developed using the programming environment in LabVIEW and is based on the fuzzy logic approach to the DGA method, interpreted by the key gas method and the Dornenburg ratio method. The developed digital model is verified on a set of 110 kV and 220 kV transformers of one of the sections of the distribution network and thermal power plant in the Russian Federation. The results obtained showed its high efficiency in predicting faults and the possibility of using it as an effective computing tool to facilitate the work of the operating personnel of power enterprises.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i2.pp1139-1146</dc:identifier><dc:identifier>10.11591/ijece.v12i2.pp1139-1146</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 2 (2022); 1139</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/25305/15458</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>