Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Evaluation of the carotid artery using wavelet-based analysis of the pulse wave signal

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 2 (2022)

DOI
10.11591/ijece.v12i2.pp1456-1467
ISSN
2722-2578, 2088-8708
Published
2022-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The use of pulse wave analysis may assist cardiologists in diagnosing patients with vascular diseases. However, it is not common in clinical practice to interpret and analyze pulse wave data and utilize them to detect the abnormalities of the signal. This paper presents a novel approach to the clinical application of pulse waveform analysis using the wavelet technique by decomposing the normal and pathology signal into many levels. The discrete wavelet transform (DWT) decomposes the carotid arterial pulse wave (CAPW) signal, and the continuous wavelet transform (CWT) creates images of the decomposed signal. The wavelet analysis technique in this work aims to strengthen the medical benefits of the pulse wave. The obtained results show a clear difference between the signal and the images of the arterial pathologies in comparison with normal ones. The certain distinct that were achieved are promising but further improvement may be required in the future.

Collaboration network of the authors

17 authors · 46 co-authorship links · 11 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Al-Ahliyya Amman University
  • Applied Science Private University
  • Amman Arab University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nidal M. TurabAl-Ahliyya Amman University4
Hamza Abu OwidaAl-Ahliyya Amman University4
Nawaf AlshdaifatApplied Science Private University3
Muneera AltayebAl-Ahliyya Amman University2
Muhammad Saleh Al-AyyadAl-Ahliyya Amman University2
Bashar E.A. BadrAl-Ahliyya Amman University1
Mwaffaq Abu-AlhaijaAl-Ahliyya Amman University1
Mohammad Abdallah AlsharaiahAl-Ahliyya Amman University1
Ala AbuthawabehAmman Arab University1
Suhaila AbuowaidaAffiliation unknown1
Ghayth AlMahadinAl-Ahliyya Amman University1
Areen M. ArabiatAl-Ahliyya Amman University1
Nour Al HawamdehAl-Ahliyya Amman University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Evaluation of the carotid artery using wavelet-based analysis of the pulse wave signal</dc:title><dc:creator>El-Sharo, Sameh</dc:creator><dc:creator>Al-Ghraibah, Amani</dc:creator><dc:creator>Al-Nabulsi, Jamal</dc:creator><dc:creator>Matalgah, Mustafa Muhammad</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;The use of pulse wave analysis may assist cardiologists in diagnosing patients with vascular diseases. However, it is not common in clinical practice to interpret and analyze pulse wave data and utilize them to detect the abnormalities of the signal. This paper presents a novel approach to the clinical application of pulse waveform analysis using the wavelet technique by decomposing the normal and pathology signal into many levels. The discrete wavelet transform (DWT) decomposes the carotid arterial pulse wave (CAPW) signal, and the continuous wavelet transform (CWT) creates images of the decomposed signal. The wavelet analysis technique in this work aims to strengthen the medical benefits of the pulse wave. The obtained results show a clear difference between the signal and the images of the arterial pathologies in comparison with normal ones. The certain distinct that were achieved are promising but further improvement may be required in the future.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i2.pp1456-1467</dc:identifier><dc:identifier>10.11591/ijece.v12i2.pp1456-1467</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 2 (2022); 1456</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/25867/15499</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>