Abstrak

Viscosity is one of the important indicators to know the condition of the lubricant. It can be measure using falling ball method, however, this method has some disadvantage. From those disadvantages, micro-controller-based viscometer rotation has been made. The design of this tool uses DC motor with rotary encoder, micro-controller ATMega16 and LCD for the display. The data taken using new and used lubricant with the code of consistency of SAE 20W-50. The result of the measurement was that the new lubricant has higher viscosity than the used one. The more dilute the oil, the less resistance occurred in the rotation of DC motor. Yet, the result has not shown the exact value of the viscosity from the oil. The tool used has not calibrated, for to be able to be calibrated, the tool needs more improvement. The data collection was took with assumption that if oil used is standard, then the value in the range of the standard reference table. From the research of test of advisability of the micro-controller-based motorized vehicle lubricant, it is known that the rotation of viscometer with the LCD display has been able to distinguish the viscosity of new and used lubricant in numbers.

Jaringan kolaborasi para penulis

29 penulis · 70 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Achmad Rifa’iAfiliasi tidak diketahui2
Abdul LatifAfiliasi tidak diketahui1
Sri Wulan Siti KhotijahAfiliasi tidak diketahui1
Sri Endah Ardhi Ningrum AbdullahAfiliasi tidak diketahui1
Dwi AtmokoAfiliasi tidak diketahui1
Achmad SopyanAfiliasi tidak diketahui1
Imam GhozaliAfiliasi tidak diketahui1
Ani RusilowatiState University of Semarang1
Arneta Dwi SafitrtriAfiliasi tidak diketahui1
Hartono HartonoAfiliasi tidak diketahui1
Nartini LestariAfiliasi tidak diketahui1
KhumaediState University of Semarang1
Khisni RohendyAfiliasi tidak diketahui1
- SusiloAfiliasi tidak diketahui1
Retno Endah SavitriAfiliasi tidak diketahui1
Vera Rizchi Cahyani PutriAfiliasi tidak diketahui1
Ahmad JuheriAfiliasi tidak diketahui1
sukiswo Supeni EdieAfiliasi tidak diketahui1
- RohmadAfiliasi tidak diketahui1
Langlang HandayaniAfiliasi tidak diketahui1
Teguh DarsonoAfiliasi tidak diketahui1
Slamet HaryonoAfiliasi tidak diketahui1
Haydnn Caesha MaulanaAfiliasi tidak diketahui1
R. IndriyantoAfiliasi tidak diketahui1
Indrawan Nur CahyonoAfiliasi tidak diketahui1
Aditya Bagus WicaksanaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/sju/index.php/upj/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 6 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">RANCANG BANGUN ALAT UJI KELAYAKAN PELUMAS KENDARAAN BERMOTOR BERBASIS MIKROKONTROLER</dc:title>
	<dc:creator>Febrianto, Teguh</dc:creator>
	<dc:creator>Edi, Sukiswo Supeni</dc:creator>
	<dc:creator>Sunarno, -</dc:creator>
	<dc:description xml:lang="en-US">Viscosity is one of the important indicators to know the condition of the lubricant. It can be measure using falling ball method, however, this method has some disadvantage. From those disadvantages, micro-controller-based viscometer rotation has been made. The design of this tool uses DC motor with rotary encoder, micro-controller ATMega16 and LCD for the display. The data taken using new and used lubricant with the code of consistency of SAE 20W-50. The result of the measurement was that the new lubricant has higher viscosity than the used one. The more dilute the oil, the less resistance occurred in the rotation of DC motor. Yet, the result has not shown the exact value of the viscosity from the oil. The tool used has not calibrated, for to be able to be calibrated, the tool needs more improvement. The data collection was took with assumption that if oil used is standard, then the value in the range of the standard reference table. From the research of test of advisability of the micro-controller-based motorized vehicle lubricant, it is known that the rotation of viscometer with the LCD display has been able to distinguish the viscosity of new and used lubricant in numbers.</dc:description>
	<dc:publisher xml:lang="en-US">Unnes Physics Journal</dc:publisher>
	<dc:date>2013-06-12</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/sju/upj/article/view/1363</dc:identifier>
	<dc:source xml:lang="en-US">Unnes Physics Journal; Vol 2 No 1 (2013)</dc:source>
	<dc:source>2252-6978</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/sju/upj/article/view/1363/1334</dc:relation>
</oai_dc:dc>