Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Protection for 330 kV transmission line and recommendation for Nigerian transmission system: a review

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 3 (2022)

DOI
10.11591/ijece.v12i3.pp3320-3334
ISSN
2722-2578, 2088-8708
Terbit
2022-06-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The transmission line is an integral part of the electrical power system; however, a fault has a negative impact on the system, like blackout, power loss, financial losses, and socio-economic impact. This fault occurs due to ageing conductors, lightning stroke, switching surge and human interference. We reviewed the protection scheme implemented in the Nigerian transmission network, which has challenges relating to the environment's terrain and a long-distance transmission line of about 20,000 km. The different approach of fault classification, detection and location was analysed and critically summarised. This review paper proposes a hybrid Artificial Neural Network and distance protection scheme that can automatically identify, locate, isolate, predict, correct faults, and real-time monitor and control the entire network. It can also detect the shortest possible trip time of 0.02 s and 0.03 s of line current and fault losses, respectively, during fault to avert damage on the line. However, this method has its challenges, such as the volume of data generated from load flow analysis, training time, and the total distance covered by the network. However, these can be averted by segmenting the entire network for easy evaluation and monitoring to achieve set goals.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Glasgow
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Protection for 330 kV transmission line and recommendation for Nigerian transmission system: a review</dc:title><dc:creator>Ogar, Vincent Nsed</dc:creator><dc:creator>Gamage, Kelum A. A.</dc:creator><dc:creator>Hussain, Sadjjad</dc:creator><dc:description>&lt;jats:p&gt;The transmission line is an integral part of the electrical power system; however, a fault has a negative impact on the system, like blackout, power loss, financial losses, and socio-economic impact. This fault occurs due to ageing conductors, lightning stroke, switching surge and human interference. We reviewed the protection scheme implemented in the Nigerian transmission network, which has challenges relating to the environment's terrain and a long-distance transmission line of about 20,000 km. The different approach of fault classification, detection and location was analysed and critically summarised. This review paper proposes a hybrid Artificial Neural Network and distance protection scheme that can automatically identify, locate, isolate, predict, correct faults, and real-time monitor and control the entire network. It can also detect the shortest possible trip time of 0.02 s and 0.03 s of line current and fault losses, respectively, during fault to avert damage on the line. However, this method has its challenges, such as the volume of data generated from load flow analysis, training time, and the total distance covered by the network. However, these can be averted by segmenting the entire network for easy evaluation and monitoring to achieve set goals.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i3.pp3320-3334</dc:identifier><dc:identifier>10.11591/ijece.v12i3.pp3320-3334</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 3 (2022); 3320</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/25119/15734</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>