Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Determining the Pareto front of distributed generator and static VAR compensator units placement in distribution networks

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 4 (2022)

DOI
10.11591/ijece.v12i4.pp3440-3453
ISSN
2722-2578, 2088-8708
Published
2022-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The integration of distributed generators (DGs), which are based on renewable energy sources, energy storage systems, and static VAR compensators (SVCs), requires considering more challenging operational cases due to the variability of DG production contributed by different characteristics for different time sequences. The size, quantity, technology, and location of DG units have major effects on the system to benefit from the integration. All these aspects create a multi-objective scope; therefore, it is considered a multi-objective mixed-integer optimization problem. This paper presents an improved multi-objective salp swarm optimization algorithm (MOSSA) to obtain multiple Pareto efficient solutions for the optimal number, location, and capacity of DGs and the controlling strategy of SVC a radial distribution system. MOSSA is a bio-inspired optimizer based on swarm intelligence techniques and it is used in finding the optimal solution for a global optimization problem. Two sets of objective functions have been formulated minimizing DGs and SVC cost, voltage violation, energy losses, and system emission cost. The usefulness of the proposed MOSSA has been tested with the 33-bus and 141-bus radial distribution systems and the qualitative comparisons against two well-known algorithms, multiple objective evolutionary algorithms based on decomposition (MOEA/D), and multiple objective particle swarm optimization (MOPSO) algorithm.

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Istanbul Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Determining the Pareto front of distributed generator and static VAR compensator units placement in distribution networks</dc:title><dc:creator>Ahmadi, Bahman</dc:creator><dc:creator>Çağlar, Ramazan</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;The integration of distributed generators (DGs), which are based on renewable energy sources, energy storage systems, and static VAR compensators (SVCs), requires considering more challenging operational cases due to the variability of DG production contributed by different characteristics for different time sequences. The size, quantity, technology, and location of DG units have major effects on the system to benefit from the integration. All these aspects create a multi-objective scope; therefore, it is considered a multi-objective mixed-integer optimization problem. This paper presents an improved multi-objective salp swarm optimization algorithm (MOSSA) to obtain multiple Pareto efficient solutions for the optimal number, location, and capacity of DGs and the controlling strategy of SVC a radial distribution system. MOSSA is a bio-inspired optimizer based on swarm intelligence techniques and it is used in finding the optimal solution for a global optimization problem. Two sets of objective functions have been formulated minimizing DGs and SVC cost, voltage violation, energy losses, and system emission cost. The usefulness of the proposed MOSSA has been tested with the 33-bus and 141-bus radial distribution systems and the qualitative comparisons against two well-known algorithms, multiple objective evolutionary algorithms based on decomposition (MOEA/D), and multiple objective particle swarm optimization (MOPSO) algorithm.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i4.pp3440-3453</dc:identifier><dc:identifier>10.11591/ijece.v12i4.pp3440-3453</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 4 (2022); 3440</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/26391/15747</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>