Abstract

Flexible plate structure provides many benefits as compared to their rigid counterparts including lower energy consumption, effective, lightweight, and quick response. However, the vibration easily affects the flexible plate structure resulting in structural damage. This study introduces the modelling of a flexible plate structure based on a system identification technique known as ant colony optimization (ACO) algorithm for vibration control. Firstly, the input-output vibration data that represent the actual structure of flexible plate was achieved from the experiment. Next, the acquired vibration data was used to develop a dynamic model of the flexible plate structure. The performances of the ACO algorithm were assess based on mean squared error (MSE), pole-zero plot and correlation test in order to get a precise and reliable outcome. The results show that ACO algorithm achieved the minimum MSE which was 6.7613×10 −6, high stability of pole-zero plot and excellent correlation test. Subsequently, the best model of ACO was chosen to create controller based on an active vibration control technique. It was noticed that the controller managed to obtain a 6.19 dB reduction at the first mode vibration in which the percentage of attenuation of the controller was 10.63% for sinusoidal disturbances and 9.64% for multiple sinusoidal disturbances.

Collaboration network of the authors

7 authors · 15 co-authorship links · 9 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknologi MARA
  • University of Technology Malaysia
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Abdul Malek Abdul WahabUniversiti Teknologi MARA2
Rickey Ting Pek EekUniversity of Technology Malaysia2
Intan Zaurah Mat DarusUniversity of Technology Malaysia2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Proportional integral derivative controller based on ant colony optimization for vibration cancellation of horizontal flexible plate structure</dc:title><dc:creator>Akmal Zamri, Muhammad Izzuddin</dc:creator><dc:creator>Hadi, Muhamad Sukri</dc:creator><dc:creator>Syafiqah Shaari, Aida Nur</dc:creator><dc:creator>Mokhtar, Nadzirah Mohd</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Flexible plate structure provides many benefits as compared to their rigid counterparts including lower energy consumption, effective, lightweight, and quick response. However, the vibration easily affects the flexible plate structure resulting in structural damage. This study introduces the modelling of a flexible plate structure based on a system identification technique known as ant colony optimization (ACO) algorithm for vibration control. Firstly, the input-output vibration data that represent the actual structure of flexible plate was achieved from the experiment. Next, the acquired vibration data was used to develop a dynamic model of the flexible plate structure. The performances of the ACO algorithm were assess based on mean squared error (MSE), pole-zero plot and correlation test in order to get a precise and reliable outcome. The results show that ACO algorithm achieved the minimum MSE which was 6.7613×10&amp;lt;sup&amp;gt;−6&amp;lt;/sup&amp;gt;, high stability of pole-zero plot and excellent correlation test. Subsequently, the best model of ACO was chosen to create controller based on an active vibration control technique. It was noticed that the controller managed to obtain a 6.19 dB reduction at the first mode vibration in which the percentage of attenuation of the controller was 10.63% for sinusoidal disturbances and 9.64% for multiple sinusoidal disturbances.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i4.pp3583-3594</dc:identifier><dc:identifier>10.11591/ijece.v12i4.pp3583-3594</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 4 (2022); 3583</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/26430/15761</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>