An optimal artificial neural network controller for load frequency control of a four-area interconnected power system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 5 (2022)

DOI
10.11591/ijece.v12i5.pp4700-4711
ISSN
2722-2578, 2088-8708
Terbit
2022-10-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this paper, an optimal artificial neural network (ANN) controller for load frequency control (LFC) of a four-area interconnected power system with non-linearity is presented. A feed forward neural network with multi-layers and Bayesian regularization backpropagation (BRB) training function is used. This controller is designed on the basis of optimal control theory to overcome the problem of load frequency control as load changes in the power system. The system comprised of transfer function models of twothermal units, one nuclear unit and one hydro unit. The controller model is developed by considering generation rate constraint (GRC) of different units as a non-linearity. The typical system parameters obtained from IEEE press power engineering series and EPRI books. The robustness, effectiveness, and performance of the proposed optimal ANN controller for a step load change and random load change in the system is simulated through using MATLAB-Simulink. The time response characteristics are compared with that obtained from the proportional, integral and derivative (PID) controller and non-linear autoregressive-moving average (NARMA-L2) controller. The results show that the algorithm developed for proposed controller has a superiority in accuracy as compared to other two controllers.

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Visvesvaraya Technological University
  • Bapuji Institute of Engineering and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Veeranjaneyulu GopuVisvesvaraya Technological University2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>An optimal artificial neural network controller for load frequency control of a four-area interconnected power system</dc:title><dc:creator>Rameshappa, Basavarajappa Sokke</dc:creator><dc:creator>Shadaksharappa, Nagaraj Mudakapla</dc:creator><dc:description>&lt;jats:p&gt;In this paper, an optimal artificial neural network (ANN) controller for load frequency control (LFC) of a four-area interconnected power system with non-linearity is presented. A feed forward neural network with multi-layers and Bayesian regularization backpropagation (BRB) training function is used. This controller is designed on the basis of optimal control theory to overcome the problem of load frequency control as load changes in the power system. The system comprised of transfer function models of twothermal units, one nuclear unit and one hydro unit. The controller model is developed by considering generation rate constraint (GRC) of different units as a non-linearity. The typical system parameters obtained from IEEE press power engineering series and EPRI books. The robustness, effectiveness, and performance of the proposed optimal ANN controller for a step load change and random load change in the system is simulated through using MATLAB-Simulink. The time response characteristics are compared with that obtained from the proportional, integral and derivative (PID) controller and non-linear autoregressive-moving average (NARMA-L2) controller. The results show that the algorithm developed for proposed controller has a superiority in accuracy as compared to other two controllers.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i5.pp4700-4711</dc:identifier><dc:identifier>10.11591/ijece.v12i5.pp4700-4711</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 5 (2022); 4700</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/26749/15895</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>