Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Development and characterization of an automated portable wound irrigation device for diabetic ulcers

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 5 (2022)

DOI
10.11591/ijece.v12i5.pp4746-4755
ISSN
2722-2578, 2088-8708
Published
2022-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Patients with diabetes mellitus may experience peripheral neuropathy and extremity system impairment, which may lead to ulceration if the treatments are delayed. Diabetic ulcers, unfortunately, are chronic, which require proper treatments, including debridement and bacterial removal using an irrigation device. To date, commercial irrigation devices included pulsed-lavage, bulb syringe, and gravity bags. Unfortunately, the devices have limitations in terms of portability, measurability, controllability, and disposability. To tackle the limitations, this study aims to design, fabricate, and characterize an automated portable wound irrigation device (Apdice), which is controllable non-disposable, and portable. The device was designed and fabricated using a lightweight construction, a rechargeable battery, and non-disposable materials to support the portability and non-disposable means. Meanwhile, the proportional-derivative-integral controller with its peripheral components were featured to enable controllability. Furthermore, the device was also tested regarding the contamination using a particle counter, and appeared to be contamination free. In short, Apdice showed a robust technological performance. However, it is also worth the try to test the contamination test against biological agents to guarantee the biocompatibility of the device.

Collaboration network of the authors

9 authors · 24 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Indonesia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nasrullah DaliAffiliation unknown1
Erwin HadisantosoAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Development and characterization of an automated portable wound irrigation device for diabetic ulcers</dc:title><dc:creator>Nadhif, Muhammad Hanif</dc:creator><dc:creator>Assyarify, Hanif</dc:creator><dc:creator>Irsyad, Muhammad</dc:creator><dc:creator>Yunir, Em</dc:creator><dc:creator>Edi Tarigan, Tri Juli</dc:creator><dc:creator>Sarumpaet, Angela</dc:creator><dc:creator>Iswati, Eni</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Patients with diabetes mellitus may experience peripheral neuropathy and extremity system impairment, which may lead to ulceration if the treatments are delayed. Diabetic ulcers, unfortunately, are chronic, which require proper treatments, including debridement and bacterial removal using an irrigation device. To date, commercial irrigation devices included pulsed-lavage, bulb syringe, and gravity bags. Unfortunately, the devices have limitations in terms of portability, measurability, controllability, and disposability. To tackle the limitations, this study aims to design, fabricate, and characterize an automated portable wound irrigation device (Apdice), which is controllable non-disposable, and portable. The device was designed and fabricated using a lightweight construction, a rechargeable battery, and non-disposable materials to support the portability and non-disposable means. Meanwhile, the proportional-derivative-integral controller with its peripheral components were featured to enable controllability. Furthermore, the device was also tested regarding the contamination using a particle counter, and appeared to be contamination free. In short, Apdice showed a robust technological performance. However, it is also worth the try to test the contamination test against biological agents to guarantee the biocompatibility of the device.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i5.pp4746-4755</dc:identifier><dc:identifier>10.11591/ijece.v12i5.pp4746-4755</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 5 (2022); 4746</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/27810/15901</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>