Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Strategy to reduce transient current of inverter-side on an average value model high voltage direct current using adaptive neuro-fuzzy inference system controller

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 5 (2022)

DOI
10.11591/ijece.v12i5.pp4790-4800
ISSN
2722-2578, 2088-8708
Published
2022-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Growing-up of high voltage direct current (HVDC) penetration into modern power systems (PS) makes difficulty on the PS operation. The HVDC produces high and slow transient current (TC) at start-time, especially for higher up-ramp rate (Urr>20 pu/s). Its condition makes the HVDC cannot be linked and synchronized into the PS rapidly. A strategy to reduce the TC is proposed by an adaptive network based fuzzy inference system (ANFIS) control on inverter HVDC-link to cope up this problem. The ANFIS control is tuned with the help of conventional control in various train-data by using offline mode. Response of ANFIS scheme is improved by suppressing TC at the values of 3.75% for the both phases (A and C), and 3.95% for phase B, for the Urr=30 pu/s. While the conventional control achieved at 9.1% for the both phases (A and B), and 9.2% for the phase C. The ANFIS control gives shorter settling time (0.553 s) than the conventional control (0.584 s) for all phases. The proposed control is more effective than the conventional control at all the scenario.

Collaboration network of the authors

14 authors · 34 co-authorship links · 11 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Mataram
  • Malikussaleh University
  • Udayana University
  • Lampung University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Agus DharmaUdayana University3
Osea ZebuaLampung University3
Arnawan HasibuanMalikussaleh University1
Farhan AkbarMalikussaleh University1
Selamat MelialaMalikussaleh University1
Rosdiana RosdianaMalikussaleh University1
Raihan PutriMalikussaleh University1
La RiandaAffiliation unknown1
Dhian HerdhiansyahAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Strategy to reduce transient current of inverter-side on an average value model high voltage direct current using adaptive neuro-fuzzy inference system controller</dc:title><dc:creator>Ginarsa, I Made</dc:creator><dc:creator>Ari Nrartha, I Made</dc:creator><dc:creator>Budi Muljono, Agung</dc:creator><dc:creator>Sultan, Sultan</dc:creator><dc:creator>Nababan, Sabar</dc:creator><dc:description>&lt;jats:p&gt;Growing-up of high voltage direct current (HVDC) penetration into modern power systems (PS) makes difficulty on the PS operation. The HVDC produces high and slow transient current (TC) at start-time, especially for higher up-ramp rate (Urr&amp;amp;gt;20 pu/s). Its condition makes the HVDC cannot be linked and synchronized into the PS rapidly. A strategy to reduce the TC is proposed by an adaptive network based fuzzy inference system (ANFIS) control on inverter HVDC-link to cope up this problem. The ANFIS control is tuned with the help of conventional control in various train-data by using offline mode. Response of ANFIS scheme is improved by suppressing TC at the values of 3.75% for the both phases (A and C), and 3.95% for phase B, for the Urr=30 pu/s. While the conventional control achieved at 9.1% for the both phases (A and B), and 9.2% for the phase C. The ANFIS control gives shorter settling time (0.553 s) than the conventional control (0.584 s) for all phases. The proposed control is more effective than the conventional control at all the scenario.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i5.pp4790-4800</dc:identifier><dc:identifier>10.11591/ijece.v12i5.pp4790-4800</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 5 (2022); 4790</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/26395/15906</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>