Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Duct quiet zones utilization for an enhancement the acoustical air-condition noise control

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 5 (2022)

DOI
10.11591/ijece.v12i5.pp4915-4925
ISSN
2722-2578, 2088-8708
Published
2022-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper investigates the duct’s noise distribution pattern due to the heating, ventilation, and air conditioning systems. This study is considering the longitudinal sound wave distribution that can permit a higher reduction of these heating, ventilation, and air conditioning systems duct noise. The proposed technique is depending on the lowest sound pressure level points in the duct or duct quiet zones. Moreover, each heating, ventilation, and air conditioning systems duct has several quiet zones, depending on the sound pressure level of the fan noise source and the duct length as well as the duct diameter. Furthermore, the noise standing wave has a wavelength (λ) which is the distance between two successive quiet zones. This work utilizes orthogonal acoustical noise with the standing wave via feed-forward control speakers. This system confirmed that the distance (λ) is linearly proportional to the duct source noise level. This system noise reduction enhancement has been fulfilled by installing further noise feed-forward control speakers at different duct quiet zones. The system simulation results were displaying satisfactory agreement with the field experimental results.

Collaboration network of the authors

6 authors · 9 co-authorship links · 5 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Al-Azhar University
  • Housing and Building National Research Center
  • Institute of Aviation Engineering & Technology
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Abdelhady Abdelazim AmmarAl-Azhar University1
Mohamed Yasin I. AfifiAl-Azhar University1
Mohamed S. ElbakryInstitute of Aviation Engineering & Technology1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Duct quiet zones utilization for an enhancement the acoustical air-condition noise control</dc:title><dc:creator>Mahmoud Kamel, Mohamed</dc:creator><dc:creator>Soliman Ahmed Said, EL-Sayed</dc:creator><dc:creator>Mohamed AL-Sagheer, Ragab</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p class="TableParagraph"&amp;gt;This paper investigates the duct’s noise distribution pattern due to the heating, ventilation, and air conditioning systems. This study is considering the longitudinal sound wave distribution that can permit a higher reduction of these heating, ventilation, and air conditioning systems duct noise. The proposed technique is depending on the lowest sound pressure level points in the duct or duct quiet zones. Moreover, each heating, ventilation, and air conditioning systems duct has several quiet zones, depending on the sound pressure level of the fan noise source and the duct length as well as the duct diameter. Furthermore, the noise standing wave has a wavelength (λ) which is the distance between two successive quiet zones. This work utilizes orthogonal acoustical noise with the standing wave via feed-forward control speakers. This system confirmed that the distance (λ) is linearly proportional to the duct source noise level. This system noise reduction enhancement has been fulfilled by installing further noise feed-forward control speakers at different duct quiet zones. The system simulation results were displaying satisfactory agreement with the field experimental results.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i5.pp4915-4925</dc:identifier><dc:identifier>10.11591/ijece.v12i5.pp4915-4925</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 5 (2022); 4915</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/26820/15918</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>