Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Design and implementation of portable electrocardiogram recorder with field programmable gate arrays and IoT interface

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 5 (2022)

DOI
10.11591/ijece.v12i5.pp5176-5181
ISSN
2722-2578, 2088-8708
Published
2022-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The electrical activities of the heart are used to monitor cardiovascular diseases. It can be measured using electrocardiogram (ECG), a simple, painless test that can be recorded graphically. The physician, to predict the patient’s heart conditions and recommend suitable treatments, uses electrodes placed on the patient’s skin surface, to record these signals. The P, Q, R, S, T waves in the ECG signal can be used to determine the normality and abnormality of the heart's condition. The time interval differs for each cardiovascular condition of the heart. In this work, the ECG signal is acquired real-time using an intelligent sensor module, and the recorded value is processed to find the peak values. The data is sent to the web serverusing internet of things technology at a minimal time, where the physician can view it and proper decision can be taken. The real-time ECG data acquisition is also made using the field programmable gate array kit as it is a low cost, high-speed device and the output is viewed in the computer. The developed model is validated through MATLAB software and implemented for real-time applications.

Collaboration network of the authors

3 authors · 3 co-authorship links · 2 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • SRM Institute of Science and Technology
  • Sri Sairam Engineering College
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Design and implementation of portable electrocardiogram recorder with field programmable gate arrays and IoT interface</dc:title><dc:creator>Rassal Raj, Nisha Rexline</dc:creator><dc:creator>Priya, Ebenezer</dc:creator><dc:creator>Savari, George Fernandez</dc:creator><dc:description>&lt;jats:p&gt;The electrical activities of the heart are used to monitor cardiovascular diseases. It can be measured using electrocardiogram (ECG), a simple, painless test that can be recorded graphically. The physician, to predict the patient’s heart conditions and recommend suitable treatments, uses electrodes placed on the patient’s skin surface, to record these signals. The P, Q, R, S, T waves in the ECG signal can be used to determine the normality and abnormality of the heart's condition. The time interval differs for each cardiovascular condition of the heart. In this work, the ECG signal is acquired real-time using an intelligent sensor module, and the recorded value is processed to find the peak values. The data is sent to the web serverusing internet of things technology at a minimal time, where the physician can view it and proper decision can be taken. The real-time ECG data acquisition is also made using the field programmable gate array kit as it is a low cost, high-speed device and the output is viewed in the computer. The developed model is validated through MATLAB software and implemented for real-time applications.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i5.pp5176-5181</dc:identifier><dc:identifier>10.11591/ijece.v12i5.pp5176-5181</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 5 (2022); 5176</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/25905/15945</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>