Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Three-phase four-wire shunt hybrid active power filter model with model predictive control in imbalance distribution networks

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 6 (2022)

DOI
10.11591/ijece.v12i6.pp5923-5937
ISSN
2722-2578, 2088-8708
Published
2022-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents a harmonic reduction and load imbalance model in a three-phase four-wire distribution network. This model uses a hybrid active power filter, a passive inductor and capacitor filter, and an active power filter in the form of a three-phase, four-leg connected grid inverter. The switching of the voltage source converter on this filter uses finite control set model predictive control (FCS-MPC). Control of this hybrid active power filter uses model predictive control (MPC) with a cost function, comparing the reference current and prediction current with mathematical modelling of the circuit. The reference current is taken from the load current by extracting dq, and the predicted current is obtained from the iteration of the voltage source converter (VSC) switching pattern. Each combination is compared with the reference current in the cost function to get the smallest error used as a power switching signal. Modelling was validated by using MATLAB Simulink. The simulation results prove a decrease in harmonics at a balanced load from 22.16% to 4.2% and at an unbalanced load, reducing the average harmonics to 4.74%. The simulation also decreases the load current imbalance in the distribution network. Reducing the current in the neutral wire from 62.01%-0.42% and 11.29-0.3 A.

Collaboration network of the authors

8 authors · 12 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Udayana University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nyoman Alvia WirayaniAffiliation unknown1
Ni Made Ary Esta Dewi WirastutiUdayana University1
Made SudarmaUdayana University1
I Gede Bagus Premana PutraUdayana University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Three-phase four-wire shunt hybrid active power filter model with model predictive control in imbalance distribution networks</dc:title><dc:creator>Andang, Asep</dc:creator><dc:creator>Hartati, Rukmi Sari</dc:creator><dc:creator>Gede Manuaba, I Bagus</dc:creator><dc:creator>Satya Kumara, I Nyoman</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;This paper presents a harmonic reduction and load imbalance model in a three-phase four-wire distribution network. This model uses a hybrid active power filter, a passive inductor and capacitor filter, and an active power filter in the form of a three-phase, four-leg connected grid inverter. The switching of the voltage source converter on this filter uses finite control set model predictive control (FCS-MPC). Control of this hybrid active power filter uses model predictive control (MPC) with a cost function, comparing the reference current and prediction current with mathematical modelling of the circuit. The reference current is taken from the load current by extracting dq, and the predicted current is obtained from the iteration of the voltage source converter (VSC) switching pattern. Each combination is compared with the reference current in the cost function to get the smallest error used as a power switching signal. Modelling was validated by using MATLAB Simulink. The simulation results prove a decrease in harmonics at a balanced load from 22.16% to 4.2% and at an unbalanced load, reducing the average harmonics to 4.74%. The simulation also decreases the load current imbalance in the distribution network. Reducing the current in the neutral wire from 62.01%-0.42% and 11.29-0.3 A.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i6.pp5923-5937</dc:identifier><dc:identifier>10.11591/ijece.v12i6.pp5923-5937</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 6 (2022); 5923</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/28747/16036</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>