Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Proposal for a fuzzy logic-based system to determine cardiovascular risk

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 6 (2022)

DOI
10.11591/ijece.v12i6.pp6058-6067
ISSN
2722-2578, 2088-8708
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

One of the key variables to determine the level of cardiovascular risk is the heart rate variability, which associates different metrics such as average of the RR intervals (average RR), standard deviation of the RR intervals (SDRR) and percentage of differences greater than 50 ms in RR intervals (pRR50). Given that these metrics make use of different measurement units, scales, and ranges, it is necessary to determine an output risk level in intelligible terms, taking as input the values of each one of them. Thus, this article proposes the development of a system based on fuzzy logic to determine the percentage or cardiovascular risk level. The fuzzy system is connected to an Arduino board with a heart rate sensor where the heart rate and heart rate variability values are obtained, so they are used to calculate the risk level metrics. Using the input values of each metric, as well as the 3 membership functions of the inputs, the output membership function, and a total of 18 inference rules defined from the inputs and outputs, the system obtains the output cardiovascular risk level. The fuzzy system was implemented using free hardware and software tools, making it available in medical campaigns for the early identification of heart conditions.

Jaringan kolaborasi para penulis

4 penulis · 5 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universidad de Cartagena
  • Universidad del Quindío
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Claudia Estella Hernández LondoñoUniversidad de Cartagena2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Proposal for a fuzzy logic-based system to determine cardiovascular risk</dc:title><dc:creator>Chanchí Golondrino, Gabriel Elías</dc:creator><dc:creator>Ospina Alarcón, Manuel Alejandro</dc:creator><dc:creator>Campo Muñoz, Wilmar Yesid</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;One of the key variables to determine the level of cardiovascular risk is the heart rate variability, which associates different metrics such as average of the RR intervals (average RR), standard deviation of the RR intervals (SDRR) and percentage of differences greater than 50 ms in RR intervals (pRR50). Given that these metrics make use of different measurement units, scales, and ranges, it is necessary to determine an output risk level in intelligible terms, taking as input the values of each one of them. Thus, this article proposes the development of a system based on fuzzy logic to determine the percentage or cardiovascular risk level. The fuzzy system is connected to an Arduino board with a heart rate sensor where the heart rate and heart rate variability values are obtained, so they are used to calculate the risk level metrics. Using the input values of each metric, as well as the 3 membership functions of the inputs, the output membership function, and a total of 18 inference rules defined from the inputs and outputs, the system obtains the output cardiovascular risk level. The fuzzy system was implemented using free hardware and software tools, making it available in medical campaigns for the early identification of heart conditions.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i6.pp6058-6067</dc:identifier><dc:identifier>10.11591/ijece.v12i6.pp6058-6067</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 6 (2022); 6058</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/28450/16048</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>