Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Computed tomography image analysis for Indonesian total hip arthroplasty designs

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 6 (2022)

DOI
10.11591/ijece.v12i6.pp6123-6131
ISSN
2722-2578, 2088-8708
Published
2022-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Total hip arthroplasty purposes to replace a hip joint damaged by an artificial hip joint. However, the developed products that already exist in the market lead to the mismatch between the hip implant equipment and the patient’s bone morphometric. Besides causing complications, the mismatch also continues to the dislocation effects, fracture, osteolysis, and thigh pain. This paper aims to design a customized hip implant based on real patient data, particularly for Indonesian patient, limited to the acetabular components and stem parts. The computed images were analyzed to estimate the patient proximal femur morphometric; those are the femoral head diameter, neck-shaft angle, mediolateral width, anteroposterior width, neck length and neck width. The experiment has succeeded in designing the acetabular shell with the thickness of 3 mm, the acetabular liner with the thickness of 6 mm, the femoral head between 22.4 to 24.8 mm, the short stem in both the right for 110.656 mm and left femur bone for 111.49 mm; that fit the patient's femur bone. Overall, the proposed steps in designing the customized hip implant in this work, based on image analysis on medical imaging data, can be a standard to be applied for other patient-needs hip arthroplasty implants.

Collaboration network of the authors

16 authors · 56 co-authorship links · 31 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Dian Nuswantoro
  • Institut Teknologi Sepuluh Nopember
  • National Research and Innovation Agency
  • University of Indonesia
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nada Fitrieyatul HikmahInstitut Teknologi Sepuluh Nopember3
Ihtifazhuddin HawariUniversitas Dian Nuswantoro2
Sheba Atma DwiyantiUniversitas Dian Nuswantoro2
Nathasya Reinelda NoviyadiUniversitas Dian Nuswantoro2
Dinda Syaqila AndryaniUniversitas Dian Nuswantoro2
Muhammad Satrio UtomoNational Research and Innovation Agency2
Tri Arief SardjonoInstitut Teknologi Sepuluh Nopember1
Ariq Dreiki HajjantoInstitut Teknologi Sepuluh Nopember1
Armand Faris A. SurbaktiInstitut Teknologi Sepuluh Nopember1
Nadhira Anindyafitri PrakosaInstitut Teknologi Sepuluh Nopember1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Computed tomography image analysis for Indonesian total hip arthroplasty designs</dc:title><dc:creator>Asmaria, Talitha</dc:creator><dc:creator>Mayasari, Dita Ayu</dc:creator><dc:creator>Gestara Febrananda, Alfensa Dinda</dc:creator><dc:creator>Nurul, Nadiya</dc:creator><dc:creator>Rahyussalim, Ahmad Jabir</dc:creator><dc:creator>Kartika, Ika</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;Total hip arthroplasty purposes to replace a hip joint damaged by an artificial hip joint. However, the developed products that already exist in the market lead to the mismatch between the hip implant equipment and the patient’s bone morphometric. Besides causing complications, the mismatch also continues to the dislocation effects, fracture, osteolysis, and thigh pain. This paper aims to design a customized hip implant based on real patient data, particularly for Indonesian patient, limited to the acetabular components and stem parts. The computed images were analyzed to estimate the patient proximal femur morphometric; those are the femoral head diameter, neck-shaft angle, mediolateral width, anteroposterior width, neck length and neck width. The experiment has succeeded in designing the acetabular shell with the thickness of 3 mm, the acetabular liner with the thickness of 6 mm, the femoral head between 22.4 to 24.8 mm, the short stem in both the right for 110.656 mm and left femur bone for 111.49 mm; that fit the patient's femur bone. Overall, the proposed steps in designing the customized hip implant in this work, based on image analysis on medical imaging data, can be a standard to be applied for other patient-needs hip arthroplasty implants.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i6.pp6123-6131</dc:identifier><dc:identifier>10.11591/ijece.v12i6.pp6123-6131</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 6 (2022); 6123</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/28453/16054</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>