Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Internet of things based real-time coronavirus 2019 disease patient health monitoring system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 6 (2022)

DOI
10.11591/ijece.v12i6.pp6806-6819
ISSN
2722-2578, 2088-8708
Published
2022-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The coronavirus disease (COVID-19) outbreak has led to many infected worldwide and has become a global crisis. COVID-19 manifests in the form of shortness of breath, coughing and fever. More people are getting infected and healthcare systems worldwide are overwhelmed as healthcare workers become exhausted and infected. Thus, remote monitoring for COVID-19 patients is required. An internet of things (IoT) based real-time health monitoring system for COVID-19 patients was proposed. It features monitoring of five physiological parameters, namely electrocardiogram (ECG), heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2) and body temperature. These vitals are processed by the main controller and transmitted to the cloud for storage. Healthcare professionals can read real-time patient vitals on the web-based dashboard which is equipped with an alert service. The proposed system was able to transmit and display all parameters in real-time accurately without any packet loss or transmission errors. The accuracy of body temperature readings, RR, SpO2 and HR, is up to 99.7%, 100%, 97.97% and 98.34%, respectively. Alerts were successfully sent when the parameters reached unsafe levels. With the proposed system, healthcare professionals can remotely monitor COVID-19 patients with greater ease, lessen their exposure to the pathogen, and improve patient monitoring.

Collaboration network of the authors

6 authors · 15 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti of Malaysia Sabah
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Internet of things based real-time coronavirus 2019 disease patient health monitoring system</dc:title><dc:creator>Ejin, Abraham Ninian</dc:creator><dc:creator>Yew, Hoe Tung</dc:creator><dc:creator>Mamat, Mazlina</dc:creator><dc:creator>Wong, Farrah</dc:creator><dc:creator>Chekima, Ali</dc:creator><dc:creator>Chung, Seng Kheau</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;The coronavirus disease (COVID-19) outbreak has led to many infected worldwide and has become a global crisis. COVID-19 manifests in the form of shortness of breath, coughing and fever. More people are getting infected and healthcare systems worldwide are overwhelmed as healthcare workers become exhausted and infected. Thus, remote monitoring for COVID-19 patients is required. An internet of things (IoT) based real-time health monitoring system for COVID-19 patients was proposed. It features monitoring of five physiological parameters, namely electrocardiogram (ECG), heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2) and body temperature. These vitals are processed by the main controller and transmitted to the cloud for storage. Healthcare professionals can read real-time patient vitals on the web-based dashboard which is equipped with an alert service. The proposed system was able to transmit and display all parameters in real-time accurately without any packet loss or transmission errors. The accuracy of body temperature readings, RR, SpO2 and HR, is up to 99.7%, 100%, 97.97% and 98.34%, respectively. Alerts were successfully sent when the parameters reached unsafe levels. With the proposed system, healthcare professionals can remotely monitor COVID-19 patients with greater ease, lessen their exposure to the pathogen, and improve patient monitoring.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i6.pp6806-6819</dc:identifier><dc:identifier>10.11591/ijece.v12i6.pp6806-6819</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 6 (2022); 6806</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/28836/16145</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>