Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Real-time wireless temperature measurement system of infant incubator

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 1 (2023)

DOI
10.11591/ijece.v13i1.pp1152-1160
ISSN
2722-2578, 2088-8708
Published
2023-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.

Collaboration network of the authors

12 authors · 42 co-authorship links · 5 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • National Research and Innovation Agency
  • University of Twente
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Yoppy YoppyNational Research and Innovation Agency2
Elvina TrividaNational Research and Innovation Agency2
Tyas Ari Wahyu WijanarkoNational Research and Innovation Agency2
Muhammad Imam SudrajatUniversity of Twente2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Real-time wireless temperature measurement system of infant incubator</dc:title><dc:creator>Sukma, Irawan</dc:creator><dc:creator>Ardiatna, Wuwus</dc:creator><dc:creator>Novitasari, Novitasari</dc:creator><dc:creator>Permatasari, Vera</dc:creator><dc:creator>Hidayat, Siddiq Wahyu</dc:creator><dc:creator>Hidayat, Asep Rahmat</dc:creator><dc:creator>Khotimah, Khusnul</dc:creator><dc:creator>Supono, Ihsan</dc:creator><dc:description>&lt;jats:p&gt;The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i1.pp1152-1160</dc:identifier><dc:identifier>10.11591/ijece.v13i1.pp1152-1160</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 1 (2023); 1152</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/26766/16282</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>