Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance analysis of a residential photovoltaic string under partial shading

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 1 (2023)

DOI
10.11591/ijece.v13i1.pp85-93
ISSN
2722-2578, 2088-8708
Terbit
2023-02-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

As one of the most prominent renewable energy resources, Photovoltaic (PV) generation has been growing dramatically over the last years and its applications are classified into residential, commercial, and power plant class, based on its power capacity. Especially, a typical residential PV system has been configured with serially connected PV modules. For serially connected PV modules, shading is a critical factor to reduce the whole string PV output power. This paper presents study on performance analysis of a residential PV string under partial shading. This analysis contains how many maximum power points (MPPs) occur and how much power would be lost while a PV string is under partial shading with different shading positions and different shading intensities. PSIM simulation tool is used to verify the performance analysis. As a result, the number of MPPs is directly related with the number of shading intensities, regardless of the shading position. In this paper, it was verified that 8 maximum power points were generated for 8 solar intensities regardless of the location of the shadows under extreme conditions. These results can be utilized for fault diagnosis in the PV string.

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Kongju National University
  • Korea Institute of Energy Research
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Seok-Cheol KoKongju National University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Performance analysis of a residential photovoltaic string under partial shading</dc:title><dc:creator>Yu, Byunggyu</dc:creator><dc:creator>Jung, Youngseok</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;As one of the most prominent renewable energy resources, Photovoltaic (PV) generation has been growing dramatically over the last years and its applications are classified into residential, commercial, and power plant class, based on its power capacity. Especially, a typical residential PV system has been configured with serially connected PV modules. For serially connected PV modules, shading is a critical factor to reduce the whole string PV output power. This paper presents study on performance analysis of a residential PV string under partial shading. This analysis contains how many maximum power points (MPPs) occur and how much power would be lost while a PV string is under partial shading with different shading positions and different shading intensities. PSIM simulation tool is used to verify the performance analysis. As a result, the number of MPPs is directly related with the number of shading intensities, regardless of the shading position. In this paper, it was verified that 8 maximum power points were generated for 8 solar intensities regardless of the location of the shadows under extreme conditions. These results can be utilized for fault diagnosis in the PV string.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i1.pp85-93</dc:identifier><dc:identifier>10.11591/ijece.v13i1.pp85-93</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 1 (2023); 85</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/28181/16177</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>