Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Power flow analysis of DC distribution system in a ship with non-electric propulsion

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 1 (2023)

DOI
10.11591/ijece.v13i1.pp9-16
ISSN
2722-2578, 2088-8708
Published
2023-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Direct current (DC) shipboard power distribution system offers higher power efficiency and voltage stability compared to the alternating current (AC) systems due to lower impedance. The implementation of DC distribution system in all-electric ship seems to be worthy since the reduction of power loss and voltage drop could overcome the drawback of DC system. However, the effectiveness of DC distribution system in ship with non-electric propulsion has not been investigated yet. Unlike in an all-electric ship, electric power flow in the distribution system of a ship with mechanic propulsion is considerably lower. The study aims to provide numerical analysis of power loss and voltage drop reduction on DC distribution system that applied to a ship with mechanic propulsion. The power flow analysis is performed on a tanker ship. Contrary to the hypothesis, the results show that the DC power distribution increase the power losses about 15% compared to AC system due to the addition of rectifier and inverter. However, the voltage drops are decreased in DC distribution system. Further investigation in the other aspects should be performed before concludes whether DC distribution system is worthy to be used in the aforementioned ship.

Collaboration network of the authors

7 authors · 12 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Institut Teknologi Sepuluh Nopember
  • Hiroshima University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Eiji ShintakuHiroshima University1
Inriyati AssaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Power flow analysis of DC distribution system in a ship with non-electric propulsion</dc:title><dc:creator>Kurniawan, Akhmad Reinaldy</dc:creator><dc:creator>Kurniawan, Adi</dc:creator><dc:creator>Sarwito, Sardono</dc:creator><dc:creator>Gumilang, Ahlur Roi Novanto</dc:creator><dc:creator>Budianto, Firman</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;Direct current (DC) shipboard power distribution system offers higher power efficiency and voltage stability compared to the alternating current (AC) systems due to lower impedance. The implementation of DC distribution system in all-electric ship seems to be worthy since the reduction of power loss and voltage drop could overcome the drawback of DC system. However, the effectiveness of DC distribution system in ship with non-electric propulsion has not been investigated yet. Unlike in an all-electric ship, electric power flow in the distribution system of a ship with mechanic propulsion is considerably lower. The study aims to provide numerical analysis of power loss and voltage drop reduction on DC distribution system that applied to a ship with mechanic propulsion. The power flow analysis is performed on a tanker ship. Contrary to the hypothesis, the results show that the DC power distribution increase the power losses about 15% compared to AC system due to the addition of rectifier and inverter. However, the voltage drops are decreased in DC distribution system. Further investigation in the other aspects should be performed before concludes whether DC distribution system is worthy to be used in the aforementioned ship.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i1.pp9-16</dc:identifier><dc:identifier>10.11591/ijece.v13i1.pp9-16</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 1 (2023); 9</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/26536/16240</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>