Abstract

Ancillary services in interconnected networks are crucial to secure real power transfers, maintaining network reliability, improving power quality as well as network stability. Reactive power has always been of special importance as one of the most substantial ancillary services required to control the voltage in power grid. This paper presents a fresh reactive power pricing approach by embedding variable transformer taps into voltage ampere reactive (var) pricing method. To carry out the resultant optimization problem with a set of complicating constraints, the genetic algorithm takes part and guarantees the global optimal solution. The simulation results show that when transformer tap works as a control variable, the total cost of reactive power can be decreased. However, the incorporation of transformer taps in the pricing model can slightly complicates voltage profiles as the sensitivity of bus voltages to the reactive power variations in the system is increased. Further, the findings reiterate that by optimal position of transformer taps, technically, the security index of the system can be enhanced while the var price for end-users (lowest purchase cost for independent system operator) being more reasonable. To simulate the proposed reactive pricing method, the standard IEEE 30-bus system is employed to analyze the proposed method.

Collaboration network of the authors

6 authors · 9 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Buein Zahra Technical University
  • Universiti Teknologi MARA
  • Sharif University of Technology
  • Universiti Malaysia Sarawak
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mohamed Abdel Moneim ShaabanUniversiti Malaysia Sarawak1
Khalid Mohamed NorAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Optimal reactive power pricing with transformer variable taps using genetic algorithm</dc:title><dc:creator>Kor, Ahmad</dc:creator><dc:creator>Zeynal, Hossein</dc:creator><dc:creator>Zakaria, Zuhaina</dc:creator><dc:creator>Hosseini, Seyed Hamid</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;Ancillary services in interconnected networks are crucial to secure real power transfers, maintaining network reliability, improving power quality as well as network stability. Reactive power has always been of special importance as one of the most substantial ancillary services required to control the voltage in power grid. This paper presents a fresh reactive power pricing approach by embedding variable transformer taps into voltage ampere reactive (var) pricing method. To carry out the resultant optimization problem with a set of complicating constraints, the genetic algorithm takes part and guarantees the global optimal solution. The simulation results show that when transformer tap works as a control variable, the total cost of reactive power can be decreased. However, the incorporation of transformer taps in the pricing model can slightly complicates voltage profiles as the sensitivity of bus voltages to the reactive power variations in the system is increased. Further, the findings reiterate that by optimal position of transformer taps, technically, the security index of the system can be enhanced while the var price for end-users (lowest purchase cost for independent system operator) being more reasonable. To simulate the proposed reactive pricing method, the standard IEEE 30-bus system is employed to analyze the proposed method.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i2.pp1272-1280</dc:identifier><dc:identifier>10.11591/ijece.v13i2.pp1272-1280</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 2 (2023); 1272</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/28082/16326</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>