Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Enhanced two-terminal impedance-based fault location using sequence values

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 2 (2023)

DOI
10.11591/ijece.v13i2.pp1291-1305
ISSN
2722-2578, 2088-8708
Published
2023-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Fault at transmission line system may lead to major impacts such as power quality problems and cascading failure in the grid system. Thus, it is very important to locate it fast so that suitable solution can be taken to ensure power system stability can be retained. The complexity of the transmission line however makes the fault point identification a challenging task. This paper proposes an enhanced fault detection and location method using positive and negative-sequence values of current and voltage, taken at both local and remote terminals. The fault detection is based on comparison between the total fault current with currents combination during the pre-fault time. While the fault location algorithm was developed using an impedance-based method and the estimated fault location was taken at two cycles after fault detection. Various fault types, fault resistances and fault locations have been tested in order to verify the performance of the proposed method. The developed algorithms have successfully detected all faults within high accuracy. Based on the obtained results, the estimated fault locations are not affected by fault resistance and line charging current. Furthermore, the proposed method able to detect fault location without the needs to know the fault type.

Collaboration network of the authors

40 authors · 133 co-authorship links · 45 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Malaysia Perlis
  • Universitas Airlangga
  • Politeknik Elektronika Negeri Surabaya
  • University of Technology Malaysia
  • Chittagong University of Engineering & Technology
  • University of Malaya
  • American International University-Bangladesh
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Prisma MegantoroUniversitas Airlangga2
P. VigneshwaranSRM Institute of Science and Technology2
Aiman Arif Mohd SallehuddinUniversiti Malaysia Perlis2
Shaiful Rizam ShamsudinUniversiti Malaysia Perlis2
Nusaybah Mohd HusinUniversiti Malaysia Perlis2
Nur Syakirah Mohammed HaniffUniversiti Malaysia Perlis2
Mahalaksmi GunasilanUniversiti Malaysia Perlis2
Melaty AmirruddinUniversiti Malaysia Perlis2
Jasrul Jamani JamianUniversity of Technology Malaysia1
Mohd Wazir MustafaUniversity of Technology Malaysia1
Muhammad Ariff BaharudinUniversity of Technology Malaysia1
N. S. B. JamiliUniversiti Malaysia Perlis1
Siti Rafidah Abdul RahimUniversiti Malaysia Perlis1
Samila Mat ZaliUniversiti Malaysia Perlis1
Muzamir IsaUniversiti Malaysia Perlis1
Hafizuddin HanafiUniversiti Malaysia Perlis1
Bambang SumantriPoliteknik Elektronika Negeri Surabaya1
Evi Nafiatus SholikhahPoliteknik Elektronika Negeri Surabaya1
Novie Ayub WindarkoPoliteknik Elektronika Negeri Surabaya1
Muhammad Nizar HabibiPoliteknik Elektronika Negeri Surabaya1
Eka PrasetyonoPoliteknik Elektronika Negeri Surabaya1
Moh. Zaenal EfendiPoliteknik Elektronika Negeri Surabaya1
Dimas Febriyan PriambodoPoliteknik Siber dan Sandi Negara1
Hafidz Faqih Aldi KusumaUniversitas Airlangga1
Yusrizal AfifUniversitas Airlangga1
Safaa Najah Saud Al-HumairiAffiliation unknown1
Arya Dwi KustiawanUniversitas Airlangga1
Muhammad Rafi Nabil ArsalanUniversitas Airlangga1
Rizki Putra PrastioUniversitas Airlangga1
Saad MekhilefUniversity of Malaya1
Aditta ChowdhuryChittagong University of Engineering & Technology1
Monirul Islam MiskatChittagong University of Engineering & Technology1
Tofael AhmedChittagong University of Engineering & Technology1
Shameem AhmadAmerican International University-Bangladesh1
Md. Rifat HazariAmerican International University-Bangladesh1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Enhanced two-terminal impedance-based fault location using sequence values</dc:title><dc:creator>Idris, Muhd Hafizi</dc:creator><dc:creator>Adzman, Mohd Rafi</dc:creator><dc:creator>Mokhlis, Hazlie</dc:creator><dc:creator>Awalin, Lilik Jamilatul</dc:creator><dc:creator>Tajuddin, Mohammad Faridun Naim</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;Fault at transmission line system may lead to major impacts such as power quality problems and cascading failure in the grid system. Thus, it is very important to locate it fast so that suitable solution can be taken to ensure power system stability can be retained. The complexity of the transmission line however makes the fault point identification a challenging task. This paper proposes an enhanced fault detection and location method using positive and negative-sequence values of current and voltage, taken at both local and remote terminals. The fault detection is based on comparison between the total fault current with currents combination during the pre-fault time. While the fault location algorithm was developed using an impedance-based method and the estimated fault location was taken at two cycles after fault detection. Various fault types, fault resistances and fault locations have been tested in order to verify the performance of the proposed method. The developed algorithms have successfully detected all faults within high accuracy. Based on the obtained results, the estimated fault locations are not affected by fault resistance and line charging current. Furthermore, the proposed method able to detect fault location without the needs to know the fault type.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i2.pp1291-1305</dc:identifier><dc:identifier>10.11591/ijece.v13i2.pp1291-1305</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 2 (2023); 1291</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/25910/16455</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>