Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

A sigma-delta interface built-in self-test and calibration for microelectromechanical system accelerometer's utilizing interpolation method

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 3 (2023)

DOI
10.11591/ijece.v13i3.pp3367-3374
ISSN
2722-2578, 2088-8708
Published
2023-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This work presents the capacitive micromechanical accelerometer with a completely differential high-order switched capacitor sigma-delta modulator interface. Such modulation interface circuit generates one-bit output data using a third sigma-delta modulator low-noise front-end, doing away with the requirement for a second enhanced converter of resolution to encode the feedback route analog signal. A capacitive micromechanical sensor unit with just a greater quality factor has been specifically employed to give greater resolution. The closed-loop and electrical correction control are used to dampen the high-Q values to get the system's stability with high-order. This microelectromechanical system (MEMS) capacitive accelerometer was calibrated using a lookup table and Akima interpolation to find manufacturing flaws by recalculating voltage levels for the test electrodes. To determine the proper electrode voltages for fault compensation, COMSOL software simulates a number of defects upon that spring as well as the fingers of the sensor system. When it comes time for the feedback phase of a proof mass displacement correction, these values are subsequently placed in the lookup table.

Collaboration network of the authors

6 authors · 7 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Babylon
  • Al-Furat Al-Awsat Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Heyam A. MarzogAl-Furat Al-Awsat Technical University1
Laith Ali Abdul-RahaimUniversity of Babylon1
Ehab AbdulRazzaq HusseinUniversity of Babylon1
Hayder Mazin Makki AlibraheemiUniversity of Babylon1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A sigma-delta interface built-in self-test and calibration for microelectromechanical system accelerometer's utilizing interpolation method</dc:title><dc:creator>Ahmed, Anwer Sabah</dc:creator><dc:creator>Al-Gayem, Qais</dc:creator><dc:description>&lt;jats:p&gt;This work presents the capacitive micromechanical accelerometer with a completely differential high-order switched capacitor sigma-delta modulator interface. Such modulation interface circuit generates one-bit output data using a third sigma-delta modulator low-noise front-end, doing away with the requirement for a second enhanced converter of resolution to encode the feedback route analog signal. A capacitive micromechanical sensor unit with just a greater quality factor has been specifically employed to give greater resolution. The closed-loop and electrical correction control are used to dampen the high-Q values to get the system's stability with high-order. This microelectromechanical system (MEMS) capacitive accelerometer was calibrated using a lookup table and Akima interpolation to find manufacturing flaws by recalculating voltage levels for the test electrodes. To determine the proper electrode voltages for fault compensation, COMSOL software simulates a number of defects upon that spring as well as the fingers of the sensor system. When it comes time for the feedback phase of a proof mass displacement correction, these values are subsequently placed in the lookup table.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i3.pp3367-3374</dc:identifier><dc:identifier>10.11591/ijece.v13i3.pp3367-3374</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 3 (2023); 3367</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/29049/16600</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>