Analysis of interference methods on transformers based on the results of dissolved gas analysis tests

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 4 (2023)

DOI
10.11591/ijece.v13i4.pp3672-3685
ISSN
2722-2578, 2088-8708
Published
2023-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In the operation of the power transformer, several maintenance efforts must be made to ensure the condition of the transformer is in good condition. The problems that usually arise are a thermal failure and electrical failure. The use of insulating media such as transformer oil and transformer insulation paper can be disrupted by this failure. Dissolved gas analysis, which identifies the types and concentrations of dissolved gas in transformer oil, can reveal details on fault indicators in power transformers (DGA). In this study, we used the interpretation of the IEEE std 2008-C57.104 (total dissolved combustible gas (TDCG), key gas, Rogers ratio method), the interpretation of IEC 2015-60599 (Duval triangle and basic gas ratio method), and the IEEE Std 2019-C57.104 interpretation (Duval pentagon method). The outcome of the DGA test is used to determine the conditions and indications of disturbances in the transformer for power. Using various gas analysis techniques also impacts the outcome of the fault indication. This variation has affected the types of gas used in the computation and the gas concentration limit value estimation. After the gas analysis, it was found that the oil purification process was also proven to reduce the concentration of combustible gases.

Collaboration network of the authors

14 authors · 31 co-authorship links · 14 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Sumatera Utara
  • Universiti Teknologi MARA
  • Kanazawa University
  • University of Technology Malaysia
  • Yangon Technological University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nur Nabila MohamedUniversiti Teknologi MARA3
Naemah MubarakahUniversitas Sumatera Utara2
Soeharwinto SoeharwintoUniversitas Sumatera Utara2
Yasunori TanakaKanazawa University1
Yanuar Zulardiansyah AriefUniversity of Technology Malaysia1
Maulaya MuhammadUniversitas Sumatera Utara1
Riswan DinziUniversitas Sumatera Utara1
Mai Kai Suan TialYangon Technological University1
Azrial Aziz Azhari NasutionUniversitas Sumatera Utara1
Farel SitumeangUniversitas Sumatera Utara1
Syahrun MubarokUniversitas Sumatera Utara1
Naomi AzhariUniversitas Sumatera Utara1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Analysis of interference methods on transformers based on the results of dissolved gas analysis tests</dc:title><dc:creator>Siregar, Yulianta</dc:creator><dc:creator>Hartanto Lumbanraja, Timothy Juan</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;In the operation of the power transformer, several maintenance efforts must be made to ensure the condition of the transformer is in good condition. The problems that usually arise are a thermal failure and electrical failure. The use of insulating media such as transformer oil and transformer insulation paper can be disrupted by this failure. Dissolved gas analysis, which identifies the types and concentrations of dissolved gas in transformer oil, can reveal details on fault indicators in power transformers (DGA). In this study, we used the interpretation of the IEEE std 2008-C57.104 (total dissolved combustible gas (TDCG), key gas, Rogers ratio method), the interpretation of IEC 2015-60599 (Duval triangle and basic gas ratio method), and the IEEE Std 2019-C57.104 interpretation (Duval pentagon method). The outcome of the DGA test is used to determine the conditions and indications of disturbances in the transformer for power. Using various gas analysis techniques also impacts the outcome of the fault indication. This variation has affected the types of gas used in the computation and the gas concentration limit value estimation. After the gas analysis, it was found that the oil purification process was also proven to reduce the concentration of combustible gases.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i4.pp3672-3685</dc:identifier><dc:identifier>10.11591/ijece.v13i4.pp3672-3685</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 4 (2023); 3672</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/30007/16764</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>