Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Multi-objective distributed generation integration in radial distribution system using modified neural network algorithm

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 5 (2023)

DOI
10.11591/ijece.v13i5.pp4810-4823
ISSN
2722-2578, 2088-8708
Published
2023-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper introduces a new approach based on a chaotic strategy and a neural network algorithm (NNA), called chaotic-based NNA (CNNA), to solve the optimal distributed generation allocation (ODGA), in the radial distribution system (RDS). This consists of determining the optimal locations and sizes of one or several distributed generations (DGs) to be inserted into the RDS to minimize one or multiple objectives while meeting a set of security limits. The robustness of the proposed method is demonstrated by applying it to two different typical RDSs, namely IEEE 33-bus and 69-bus. In this regard, simulations are performed for three DGs in the cases of unity power factor (UPF) and optimal power factor (OPF), considering single and multi-objective optimization, by minimizing the total active losses and improving the voltage profile, voltage deviation (VD) and voltage stability index (VSI). Compared to its original version and recently reported methods, the CNNA solutions are more competitive without increasing the complexity of the optimization algorithm, especially when the RDS size and problem dimension are extended.

Collaboration network of the authors

16 authors · 47 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Hassan II Casablanca
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Jamal BoukherouaaUniversity of Hassan II Casablanca16
Faissal ElmariamiUniversity of Hassan II Casablanca8
Nazha CherkaouiAffiliation unknown6
Mohamed Nouh DazahraAffiliation unknown4
Tayeb OuaderhmanUniversity of Hassan II Casablanca4
Abdelmajid BerdaiUniversity of Hassan II Casablanca4
Elmahdi KhoudryUniversity of Hassan II Casablanca3
Touria HaidiUniversity of Hassan II Casablanca3
Anass LekbichUniversity of Hassan II Casablanca3
Bouchra CheddadiUniversity of Hassan II Casablanca1
Zineb El IdrissiUniversity of Hassan II Casablanca1
Ali TarrakAffiliation unknown1
Chaimae ZedakUniversity of Hassan II Casablanca1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Multi-objective distributed generation integration in radial distribution system using modified neural network algorithm</dc:title><dc:creator>Tarraq, Ali</dc:creator><dc:creator>El Mariami, Faissal</dc:creator><dc:creator>Belfqih, Abdelaziz</dc:creator><dc:description>&lt;jats:p&gt;This paper introduces a new approach based on a chaotic strategy and a neural network algorithm (NNA), called chaotic-based NNA (CNNA), to solve the optimal distributed generation allocation (ODGA), in the radial distribution system (RDS). This consists of determining the optimal locations and sizes of one or several distributed generations (DGs) to be inserted into the RDS to minimize one or multiple objectives while meeting a set of security limits. The robustness of the proposed method is demonstrated by applying it to two different typical RDSs, namely IEEE 33-bus and 69-bus. In this regard, simulations are performed for three DGs in the cases of unity power factor (UPF) and optimal power factor (OPF), considering single and multi-objective optimization, by minimizing the total active losses and improving the voltage profile, voltage deviation (VD) and voltage stability index (VSI). Compared to its original version and recently reported methods, the CNNA solutions are more competitive without increasing the complexity of the optimization algorithm, especially when the RDS size and problem dimension are extended.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i5.pp4810-4823</dc:identifier><dc:identifier>10.11591/ijece.v13i5.pp4810-4823</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 5 (2023); 4810</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/30379/16785</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>