Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Fine-tuning U-net for medical image segmentation based on activation function, optimizer and pooling layer

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 5 (2023)

DOI
10.11591/ijece.v13i5.pp5406-5417
ISSN
2722-2578, 2088-8708
Published
2023-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

U-net convolutional neural network (CNN) is a famous architecture developed to deal with medical images. Fine-tuning CNNs is a common technique used to enhance their performance by selecting the building blocks which can provide the ultimate results. This paper introduces a method for tuning U-net architecture to improve its performance in medical image segmentation. The experiment is conducted using an x-ray image segmentation approach. The performance of U-net CNN in lung x-ray image segmentation is studied with different activation functions, optimizers, and pooling-bottleneck-layers. The analysis focuses on creating a method that can be applied for tuning U-net, like CNNs. It also provides the best activation function, optimizer, and pooling layer to enhance U-net CNN’s performance on x-ray image segmentation. The findings of this research showed that a U-net architecture worked supremely when we used the LeakyReLU activation function and average pooling layer as well as RMSProb optimizer. The U-net model accuracy is raised from 89.59 to 93.81% when trained and tested with lung x-ray images and uses the LeakyReLU activation function, average pooling layer, and RMSProb optimizer. The fine-tuned model also enhanced accuracy results with three other datasets.

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Princess Sumaya University for Technology
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Fine-tuning U-net for medical image segmentation based on activation function, optimizer and pooling layer</dc:title><dc:creator>Younisse, Remah</dc:creator><dc:creator>Ghnemat, Rawan</dc:creator><dc:creator>Al Saraireh, Jaafer</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;U-net convolutional neural network (CNN) is a famous architecture developed to deal with medical images. Fine-tuning CNNs is a common technique used to enhance their performance by selecting the building blocks which can provide the ultimate results. This paper introduces a method for tuning U-net architecture to improve its performance in medical image segmentation. The experiment is conducted using an x-ray image segmentation approach. The performance of U-net CNN in lung x-ray image segmentation is studied with different activation functions, optimizers, and pooling-bottleneck-layers. The analysis focuses on creating a method that can be applied for tuning U-net, like CNNs. It also provides the best activation function, optimizer, and pooling layer to enhance U-net CNN’s performance on x-ray image segmentation. The findings of this research showed that a U-net architecture worked supremely when we used the LeakyReLU activation function and average pooling layer as well as RMSProb optimizer. The U-net model accuracy is raised from 89.59 to 93.81% when trained and tested with lung x-ray images and uses the LeakyReLU activation function, average pooling layer, and RMSProb optimizer. The fine-tuned model also enhanced accuracy results with three other datasets.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i5.pp5406-5417</dc:identifier><dc:identifier>10.11591/ijece.v13i5.pp5406-5417</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 5 (2023); 5406</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/30488/16839</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>