PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI

JOURNAL ONLINE OF PHYSICS · Vol. 3 No. 1 (2018) · hlm. 14–22

DOI
10.22437/jop.v3i1.4428
ISSN
2502-2016
Terbit
2018-08-01
Penerbit
Prodi Fisika FST UNJA
Bahasa
en

Abstrak

The research on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.

Jaringan kolaborasi para penulis

22 penulis · 46 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Muslim Indonesia
  • The University of Adelaide
  • State University of Malang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Samratul FuadyAfiliasi tidak diketahui2
Dasrinal TessalAfiliasi tidak diketahui2
Yosi Riduas HaisAfiliasi tidak diketahui2
Sri PurwaningsihAfiliasi tidak diketahui2
Aprilia SulistaAfiliasi tidak diketahui1
Widiansyah ArdiAfiliasi tidak diketahui1
Bima Tondi Innatta HarahapAfiliasi tidak diketahui1
Oki SaputraAfiliasi tidak diketahui1
Arif Rahman HakimAfiliasi tidak diketahui1
Amelinda Callista Devina InonuAfiliasi tidak diketahui1
Samsidar SamsidarUniversitas Muslim Indonesia1
Sri OktamulianiAfiliasi tidak diketahui1
Nazri MZAfiliasi tidak diketahui1
Jufrida JufridaAfiliasi tidak diketahui1
jules julesAfiliasi tidak diketahui1
Wawan KurniawanThe University of Adelaide1
Abdul ManabAfiliasi tidak diketahui1
Ardo AlensyahAfiliasi tidak diketahui1
Cicyn RiantoniState University of Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://online-journal.unja.ac.id/index.php/jop/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI</dc:title>
	<dc:creator xml:lang="en">sparzinanda, eif</dc:creator>
	<dc:creator xml:lang="en">Nehru, Nehru</dc:creator>
	<dc:creator xml:lang="en">nurhidayah, nurhidayah</dc:creator>
	<dc:description xml:lang="en">The research &amp;nbsp;on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.</dc:description>
	<dc:publisher xml:lang="en">Prodi Fisika FST UNJA</dc:publisher>
	<dc:date>2018-08-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://online-journal.unja.ac.id/jop/article/view/4428</dc:identifier>
	<dc:identifier>10.22437/jop.v3i1.4428</dc:identifier>
	<dc:source xml:lang="en">JOURNAL ONLINE OF PHYSICS; Vol. 3 No. 1 (2017): JOP (Journal Online of Physics) Vol 3 No 1; 14-22</dc:source>
	<dc:source>2502-2016</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://online-journal.unja.ac.id/jop/article/view/4428/8676</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2017 JOURNAL ONLINE OF PHYSICS</dc:rights>
</oai_dc:dc>