Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Optimal inverter-based distributed generation in ULP Way Halim considering harmonic distortion

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 6 (2023)

DOI
10.11591/ijece.v13i6.pp6058-6067
ISSN
2722-2578, 2088-8708
Published
2023-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Integration of distributed generation (DG) based on the use of new renewable energy is considered to be able to increase the capability of the electric power distribution system. However, the use of inverter-based DG is not optimal, it can worsen the condition of the system, especially in terms of the spread of harmonic distortion which can damage the equipment. This is due to the inverter-based DG technology, apart from supplying electrical energy, DG also injects harmonic currents from existing semiconductor components. This research discusses optimization placement of inverter-based DG using the multi objective particle swarm optimization (MOPSO) method which was tested on the Unit Layanan Pelaksana (ULP) Way Halim 88-bus radial distribution system based on MALTAB 2020b to increase the efficiency of the electrical system by reducing losses and %THDv. The inverter-based DG placed on 24 bus points with a capacity of 690 kW can reduce losses by up to 12.74 kW or 14.96% and all %THDv values for each bus are below 5%.

Collaboration network of the authors

26 authors · 108 co-authorship links · 73 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Politeknik Negeri Ujung Pandang
  • Institut Teknologi Sepuluh Nopember
  • Politeknik Bosowa
  • State University of Makassar
  • Universitas Muhammadiyah Metro
  • Tadulako University
  • Khairun University
  • Other organisations
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ontoseno PenangsangInstitut Teknologi Sepuluh Nopember5
Muhammad Daffa CahyonoputraInstitut Teknologi Sepuluh Nopember3
Dimas Fajar Uman PutraInstitut Teknologi Sepuluh Nopember3
Rony Seto WibowoInstitut Teknologi Sepuluh Nopember2
Yuli Asmi RahmanTadulako University2
Sarma ThahaPoliteknik Negeri Ujung Pandang2
Musfirah Putri LukmanPoliteknik Negeri Ujung Pandang2
Asma AmaliahPoliteknik Negeri Ujung Pandang2
Mustika MustikaUniversitas Muhammadiyah Metro2
Mochammad Apriyadi Hadi SiradKhairun University2
Anisya SonitaUniversitas Muhammadiyah Bengkulu2
Nurhayati NurhayatiPoliteknik Negeri Ujung Pandang1
Nur HidayahPoliteknik Negeri Ujung Pandang1
Muh. AhyarPoliteknik Negeri Ujung Pandang1
Asriyadi AsriyadiPoliteknik Negeri Ujung Pandang1
Yuniarti YuniartiPoliteknik Negeri Ujung Pandang1
Mustika MustikaUniversitas Muhammadiyah Metro1
Asmah AkhrianaUniversitas DIPA Makassar1
Mukhlisin MukhlisinState University of Makassar1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Optimal inverter-based distributed generation in ULP Way Halim considering harmonic distortion</dc:title><dc:creator>Sofyan, Sofyan</dc:creator><dc:creator>Faraby, Muhira Dzar</dc:creator><dc:creator>Akhmad, Satriani Said</dc:creator><dc:creator>Gaffar, Ahmad</dc:creator><dc:creator>Fitriati, Andi</dc:creator><dc:creator>Elviralita, Yoan</dc:creator><dc:creator>Muchtar, Akhyar</dc:creator><dc:description>&lt;jats:p&gt;Integration of distributed generation (DG) based on the use of new renewable energy is considered to be able to increase the capability of the electric power distribution system. However, the use of inverter-based DG is not optimal, it can worsen the condition of the system, especially in terms of the spread of harmonic distortion which can damage the equipment. This is due to the inverter-based DG technology, apart from supplying electrical energy, DG also injects harmonic currents from existing semiconductor components. This research discusses optimization placement of inverter-based DG using the multi objective particle swarm optimization (MOPSO) method which was tested on the Unit Layanan Pelaksana (ULP) Way Halim 88-bus radial distribution system based on MALTAB 2020b to increase the efficiency of the electrical system by reducing losses and %THDv. The inverter-based DG placed on 24 bus points with a capacity of 690 kW can reduce losses by up to 12.74 kW or 14.96% and all %THDv values for each bus are below 5%.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i6.pp6058-6067</dc:identifier><dc:identifier>10.11591/ijece.v13i6.pp6058-6067</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 6 (2023); 6058</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/32010/16934</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>