Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Two-link lower limb exoskeleton model control enhancement using computed torque

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 6 (2023)

DOI
10.11591/ijece.v13i6.pp6204-6215
ISSN
2722-2578, 2088-8708
Published
2023-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Robotic technology has recently been used to help stroke patients with gait and balance rehabilitation. Rehabilitation robots such as gait trainers are designed to assist patients in systematic, repetitive training sessions to speed up their recovery from injuries. Several control algorithms are commonly used on exoskeletons, such as proportional, integral and derivative (PID) as linear control. However, linear control has several disadvantages when applied to the exoskeleton, which has the problem of uncertainties such as load and stiffness variations of the patient’s lower limb. To improve the lower limb exoskeleton for the gait trainer, the computed torque controller (CTC) is introduced as a control approach in this study. When the dynamic properties of the system are only partially known, the computed torque controller is an essential nonlinear controller. A mathematical model forms the foundation of this controller. The suggested control approach’s effectiveness is evaluated using a model or scaled-down variation of the method. The performance of the suggested calculated torque control technique is then evaluated and contrasted with that of the PID controller. Because of this, the PID controller’s steady-state error in the downward direction can reach 5.6%, but the CTC can lower it to 2.125%.

Collaboration network of the authors

7 authors · 10 co-authorship links · 5 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Rajamangala University of Technology
  • Institut Teknologi Dan Bisnis STIKOM Bali
  • Sanata Dharma University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Padma Nyoman CrisnapatiRajamangala University of Technology2
Evi TriandiniInstitut Teknologi Dan Bisnis STIKOM Bali2
Petrus SutyasadiSanata Dharma University2
Yamin ThweRajamangala University of Technology1
I Komang Agus Ady AryantoRajamangala University of Technology1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Two-link lower limb exoskeleton model control enhancement using computed torque</dc:title><dc:creator>Parikesit, Elang</dc:creator><dc:creator>Maneetham, Dechrit</dc:creator><dc:description>&lt;jats:p&gt;Robotic technology has recently been used to help stroke patients with gait and balance rehabilitation. Rehabilitation robots such as gait trainers are designed to assist patients in systematic, repetitive training sessions to speed up their recovery from injuries. Several control algorithms are commonly used on exoskeletons, such as proportional, integral and derivative (PID) as linear control. However, linear control has several disadvantages when applied to the exoskeleton, which has the problem of uncertainties such as load and stiffness variations of the patient’s lower limb. To improve the lower limb exoskeleton for the gait trainer, the computed torque controller (CTC) is introduced as a control approach in this study. When the dynamic properties of the system are only partially known, the computed torque controller is an essential nonlinear controller. A mathematical model forms the foundation of this controller. The suggested control approach’s effectiveness is evaluated using a model or scaled-down variation of the method. The performance of the suggested calculated torque control technique is then evaluated and contrasted with that of the PID controller. Because of this, the PID controller’s steady-state error in the downward direction can reach 5.6%, but the CTC can lower it to 2.125%.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i6.pp6204-6215</dc:identifier><dc:identifier>10.11591/ijece.v13i6.pp6204-6215</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 6 (2023); 6204</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/32046/16946</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>