Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

SISTEM MONITORING KWH METER DIGITAL BERBASIS IOT PADA LABORATORIUM PERALATAN MEDIS

JOURNAL ONLINE OF PHYSICS · Vol. 8 No. 3 (2023) · hlm. 80–86

DOI
10.22437/jop.v8i3.26931
ISSN
2502-2016
Terbit
2023-07-31
Penerbit
Prodi Fisika FST UNJA
Bahasa
en

Abstrak

The educational process, which is supported by adequate laboratory facilities and infrastructure, will produce professional higher education tri-dharma outputs, both for students and lecturers. The Medical Equipment Laboratory is a place where experimental studies with various equipment and devices, analyses, and observations are carried out. The amount of electrical energy used by a university can be measured using an electric energy meter, namely the kWh meter, but the university cannot monitor which building or room uses the most electrical energy because it only knows the amount of power used each month. Given these problems, a digital kWh Meter monitoring tool based on the Internet of Things (IoT) is designed to measure the amount of current, voltage, power, and costs that must be incurred while using medical equipment and can then be monitored in real time using the Blynk application as the server. The implementation system for monitoring the kwh meter using the PZEM-004T sensor has a very good accuracy rate of 99.52% for measuring voltage and 99.87% for measuring current on medical equipment in the medical equipment laboratory at the PGRI Yogyakarta University. It was found that the greater the applied load value, the more the impact on data outputs such as current and voltage would affect the size of the monthly electricity bill. The monitoring system can be carried out within a radius of 20 meters as long as the smartphone is connected to a WiFi connection. Monitoring activities and electrical device control activities can be carried out.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas PGRI Yogyakarta
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://online-journal.unja.ac.id/index.php/jop/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">SISTEM MONITORING KWH METER DIGITAL BERBASIS IOT PADA LABORATORIUM PERALATAN MEDIS</dc:title>
	<dc:creator xml:lang="en">Widyawarman, Danang</dc:creator>
	<dc:creator xml:lang="en">Hastono, Tri</dc:creator>
	<dc:subject xml:lang="en">Laboratory; kWh Meter; IoT; PZEM-004T sensor; Monitoring</dc:subject>
	<dc:description xml:lang="en">The educational process, which is supported by adequate laboratory facilities and infrastructure, will produce professional higher education tri-dharma outputs, both for students and lecturers. The Medical Equipment Laboratory is a place where experimental studies with various equipment and devices, analyses, and observations are carried out. The amount of electrical energy used by a university can be measured using an electric energy meter, namely the kWh meter, but the university cannot monitor which building or room uses the most electrical energy because it only knows the amount of power used each month. Given these problems, a digital kWh Meter monitoring tool based on the Internet of Things (IoT) is designed to measure the amount of current, voltage, power, and costs that must be incurred while using medical equipment and can then be monitored in real time using the Blynk application as the server. The implementation system for monitoring the kwh meter using the PZEM-004T sensor has a very good accuracy rate of 99.52% for measuring voltage and 99.87% for measuring current on medical equipment in the medical equipment laboratory at the PGRI Yogyakarta University. It was found that the greater the applied load value, the more the impact on data outputs such as current and voltage would affect the size of the monthly electricity bill. The monitoring system can be carried out within a radius of 20 meters as long as the smartphone is connected to a WiFi connection. Monitoring activities and electrical device control activities can be carried out.
&amp;nbsp;</dc:description>
	<dc:publisher xml:lang="en">Prodi Fisika FST UNJA</dc:publisher>
	<dc:date>2023-07-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://online-journal.unja.ac.id/jop/article/view/26931</dc:identifier>
	<dc:identifier>10.22437/jop.v8i3.26931</dc:identifier>
	<dc:source xml:lang="en">JOURNAL ONLINE OF PHYSICS; Vol. 8 No. 3 (2023): JOP (Journal Online of Physics) Vol 8 No 3; 80-86</dc:source>
	<dc:source>2502-2016</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://online-journal.unja.ac.id/jop/article/view/26931/16243</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2023 JOURNAL ONLINE OF PHYSICS</dc:rights>