Akses terbuka
Jurnal
Tanpa peringkat SINTA
ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR
JOURNAL ONLINE OF PHYSICS · Vol. 10 No. 1 (2024) · hlm. 55–61
ISSN 2502-2016
Terbit 2024-11-08
Penerbit Prodi Fisika FST UNJA
Bahasa en
Abstrak
This research aims to determine the CTDI value on a CT Scan aircraft using Dose Profiler and to determine the comparison of the CTDI (Computed Tomography Dose Index) value on the surface of each measurement position. The measurement method was carried out by measuring the CT Scan radiation dose with the CTDI value on the phantom using a RaySafe multimeter at a voltage of 130 kV, using a thickness of 10 mm, a time current accuracy of 100 mAs, 200 mAs and 300 mAs. The research results show the dose received on the surface of each type of phantom position with different time current accuracy respectively for a time current of 100 mAs at the center (9.139 mGy), type 1 (9.606 mGy), type 2 (9.170) type 3 (9.221), and type 4 (9,210). A time current of 200 mAs is found at the center (9,110 mGy), edge 1 (9,578 mGy), edge 2 (9,546 mGy), edge 3 (9,224 mGy), and edge 4 (9,200 mGy). A time current of 300 mAs is found at the center position (18.39 mGy), edge 1 (19.33 mGy), edge 2 (19.18 mGy), edge 3 (18.48 mGy), and 4 (18.51 mGy). Time-current variations affect the radiation dose that can be received by the phantom and have a linear influence on the CTDIvol value.
Jaringan kolaborasi para penulis
7 penulis ·
12 tautan kepenulisan bersama
· 5 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas Islam Negeri Alauddin Makassar IPB University Universitas Sulawesi Barat Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://online-journal.unja.ac.id/index.php/jop/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR</dc:title>
<dc:creator xml:lang="en">Ilham, Ilham</dc:creator>
<dc:creator xml:lang="en">Zelviani, Sri</dc:creator>
<dc:creator xml:lang="en">Jumardin, Jumardin</dc:creator>
<dc:creator xml:lang="en">Bariah, Khaerul</dc:creator>
<dc:subject xml:lang="en">CTDI;</dc:subject>
<dc:subject xml:lang="en">CT Scan;</dc:subject>
<dc:subject xml:lang="en">Dose Profiler;</dc:subject>
<dc:subject xml:lang="en">Head Phantom;</dc:subject>
<dc:description xml:lang="en">This research aims to determine the CTDI value on a CT Scan aircraft using&nbsp; Dose Profiler and to determine the comparison of the CTDI (Computed Tomography Dose Index) value on the surface of each measurement position. The measurement method was carried out by measuring the CT Scan radiation dose with the CTDI value on the phantom using a RaySafe multimeter at a voltage of 130 kV, using a thickness of 10 mm, a time current accuracy of 100 mAs, 200 mAs and 300 mAs. The research results show the dose received on the surface of each type of phantom position with different time current accuracy respectively for a time current of 100 mAs at the center (9.139 mGy), type 1 (9.606 mGy), type 2 (9.170) type 3 (9.221) , and type 4 (9,210). A time current of 200 mAs is found at the center (9,110 mGy), edge 1 (9,578 mGy), edge 2 (9,546 mGy), edge 3 (9,224 mGy), and edge 4 (9,200 mGy). A time current of 300 mAs is found at the center position (18.39 mGy), edge 1 (19.33 mGy), edge 2 (19.18 mGy), edge 3 (18.48 mGy), and 4 (18.51 mGy) . Time-current variations affect the radiation dose that can be received by the phantom and have a linear influence on the CTDIvol value.</dc:description>
<dc:publisher xml:lang="en">Prodi Fisika FST UNJA</dc:publisher>
<dc:date>2024-11-08</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://online-journal.unja.ac.id/jop/article/view/37149</dc:identifier>
<dc:identifier>10.22437/jop.v10i1.37149</dc:identifier>
<dc:source xml:lang="en">JOURNAL ONLINE OF PHYSICS; Vol. 10 No. 1 (2024): JOP (Journal Online of Physics) Vol 10 No 1; 55-61</dc:source>
<dc:source>2502-2016</dc:source>
<dc:language>en</dc:language>
<dc:relation>https://online-journal.unja.ac.id/jop/article/view/37149/19299</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2024 Ilham Ilham, Sri Zelviani, Jumardin Jumardin, Khaerul Bariah</dc:rights>
<dc:rights xml:lang="en">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Ilham, I., Zelviani, S., Jumardin, J., & Bariah, K. (2024). ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR. JOURNAL ONLINE OF PHYSICS, 10(1), 55–61. https://doi.org/10.22437/jop.v10i1.37149
Salin
IEEE
I. Ilham, S. Zelviani, J. Jumardin, and K. Bariah, “ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR,” JOURNAL ONLINE OF PHYSICS, vol. 10, no. 1, pp. 55–61, 2024, doi: 10.22437/jop.v10i1.37149.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.