Melola Discovery

← Melola Discovery

Akses terbuka Jurnal Tanpa peringkat SINTA

GAS CONCENTRATION MEASUREMENTS OF C2H2 USING A CALIBRATION RELATION OF TDLS SPECTROMETER

JOURNAL ONLINE OF PHYSICS · Vol. 10 No. 3 (2025) · hlm. 135–140

DOI
10.22437/jop.v10i3.47025
ISSN
2502-2016
Terbit
2025-07-27
Penerbit
Prodi Fisika FST UNJA
Bahasa
en
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

The work has been demonstrated by varying the wavelength of a tunable DFB laser diode, a Tunable Diode Laser Spectroscopy (TDLS) simulation method employing a sinusoidal signal to enhances the sensitivity of the spectrometer. Since the laser drive current is tuned, altering the current will cause the laser diode's wavelength to shift within the Near Infrared (NIR) tuning range of around 0.02 nm. A set focus value of 0.5 ppm and a fixed open path length (distance between laser source and back reflector) of 100 m were used to evaluate the TDLS's sensitivity. A MATLAB code was written to change the exact wavelength of the near infrared region, and the frequency domain evaluations were taken to extract the value of the second harmonic, which is an indication of the presence of the gas to be detected. The value of wavelength has been found in NIR region of the acetylene was about 1530. 47 nm. It should be noted the amount of gas concentrations were performed at a distance of 100 meters, with the gas concentration being N = 0.05 to 0.5 ppm in 0.2 increments.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Babylon
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://online-journal.unja.ac.id/index.php/jop/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">GAS CONCENTRATION MEASUREMENTS OF C2H2 USING A CALIBRATION RELATION OF TDLS SPECTROMETER</dc:title>
	<dc:creator xml:lang="en">Mahmood, Ruaa Kahtan</dc:creator>
	<dc:creator xml:lang="en">Sekeb, Amani Ali</dc:creator>
	<dc:creator xml:lang="en">Deindee, Tabarek Falah</dc:creator>
	<dc:creator xml:lang="en"> Al Masoudi, Amal Abd Al-Amir</dc:creator>
	<dc:subject xml:lang="en">TDLS</dc:subject>
	<dc:subject xml:lang="en">Acetylene Gas</dc:subject>
	<dc:subject xml:lang="en">wavelength tuning</dc:subject>
	<dc:subject xml:lang="en">Remote sensors</dc:subject>
	<dc:subject xml:lang="en">laser detector</dc:subject>
	<dc:description xml:lang="en">The work has been demonstrated by varying the wavelength of a tunable DFB laser diode, a Tunable Diode Laser Spectroscopy (TDLS) simulation method employing a sinusoidal signal to enhances the sensitivity of the spectrometer. Since the laser drive current is tuned, altering the current will cause the laser diode's wavelength to shift within the Near Infrared (NIR) tuning range of around 0.02 nm. A set focus value of 0.5 ppm and a fixed open path length (distance between laser source and back reflector) of 100 m were used to evaluate the TDLS's sensitivity. A MATLAB code was written to change the exact wavelength of the near infrared region, and the frequency domain evaluations were taken to extract the value of the second harmonic, which is an indication of the presence of the gas to be detected. The value of wavelength has been found in NIR region of the acetylene was about 1530. 47 nm. It should be noted the amount of gas concentrations were performed at a distance of 100 meters, with the gas concentration being N = 0.05 to 0.5 ppm in 0.2 increments.</dc:description>
	<dc:publisher xml:lang="en">Prodi Fisika FST UNJA</dc:publisher>
	<dc:date>2025-07-27</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://online-journal.unja.ac.id/jop/article/view/47025</dc:identifier>
	<dc:identifier>10.22437/jop.v10i3.47025</dc:identifier>
	<dc:source xml:lang="en">JOURNAL ONLINE OF PHYSICS; Vol. 10 No. 3 (2025): JOP (Journal Online of Physics) Vol 10 No 3; 135-140</dc:source>
	<dc:source>2502-2016</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://online-journal.unja.ac.id/jop/article/view/47025/21735</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Ruaa Kahtan Mahmood, Amani Ali Sekeb, Tabarek Falah Deindee, Amal Abd Al-Amir  Al Masoudi</dc:rights>
	<dc:rights xml:lang="en">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>