Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Varying the energisation condition to mitigate sympathetic inrush current

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 6 (2023)

DOI
10.11591/ijece.v13i6.pp5975-5985
ISSN
2722-2578, 2088-8708
Published
2023-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Transformers are generally easy to access and can contribute significantly to entire power system. When a transformer is turned on for the first time, it produces a magnetising inrush current which acts as a starting current. Energisation of transformer has a substantial impact on inrush current and transformer that are connected in parallel. Sympathetic inrush current is a phenomenon that appears when a transformer is switched-on in network whereas the other transformers that was earlier energised. Besides, when sympathetic inrush phenomena occur, the peak and period fluctuate significantly. In this paper, the transformers will be energised in three different ways and each condition will be explored in depth. The operation time of the transformer’s energisation whether it is energised simultaneously or at different times are tested and analysed in terms of their characteristics. It is performed using power system computer aided design (PSCAD) software, starting with a develop model of the energisation and then generate the outcomes. The results of the simulation demonstrate that energising the transformer in different ways can give different effect on the sympathetic inrush current, as well as the variables that affect it and methods for reducing it.

Collaboration network of the authors

11 authors · 24 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Malaysia Perlis
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
N. S. B. JamiliUniversiti Malaysia Perlis1
Mohd Rafi AdzmanUniversiti Malaysia Perlis1
Siti Rafidah Abdul RahimUniversiti Malaysia Perlis1
Muzamir IsaUniversiti Malaysia Perlis1
Hafizuddin HanafiUniversiti Malaysia Perlis1
Noor Fazliana FadzailUniversiti Malaysia Perlis1
Ernie Che MidUniversiti Malaysia Perlis1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Varying the energisation condition to mitigate sympathetic inrush current</dc:title><dc:creator>Nadhirah, Nurul Fatin</dc:creator><dc:creator>Halim, Hana Abdull</dc:creator><dc:creator>Mukhtar, Nurhakimah Mohd</dc:creator><dc:creator>Zali, Samila Mat</dc:creator><dc:description>&lt;jats:p&gt;Transformers are generally easy to access and can contribute significantly to entire power system. When a transformer is turned on for the first time, it produces a magnetising inrush current which acts as a starting current. Energisation of transformer has a substantial impact on inrush current and transformer that are connected in parallel. Sympathetic inrush current is a phenomenon that appears when a transformer is switched-on in network whereas the other transformers that was earlier energised. Besides, when sympathetic inrush phenomena occur, the peak and period fluctuate significantly. In this paper, the transformers will be energised in three different ways and each condition will be explored in depth. The operation time of the transformer’s energisation whether it is energised simultaneously or at different times are tested and analysed in terms of their characteristics. It is performed using power system computer aided design (PSCAD) software, starting with a develop model of the energisation and then generate the outcomes. The results of the simulation demonstrate that energising the transformer in different ways can give different effect on the sympathetic inrush current, as well as the variables that affect it and methods for reducing it.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i6.pp5975-5985</dc:identifier><dc:identifier>10.11591/ijece.v13i6.pp5975-5985</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 6 (2023); 5975</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/30494/16927</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>