Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Development of spiral square coils for magnetic labelling detection in microfluidic systems

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 6 (2023)

DOI
10.11591/ijece.v13i6.pp6037-6046
ISSN
2722-2578, 2088-8708
Published
2023-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Due to the development of microfluidic systems biomedical microelectromechanical systems (BioMEMS) for magnetic labelling detection by magnetic microbeads circling in microfluidic channels, we used the magnetic field created by microcoils. The magnetic field associated with the electric current, but with negatively affects if its value increases too much. Handling bio-species in the microfluidic chip requires that the temperature maintained to keep the cells to prevent their destruction. In this paper we have described the spiral square coil design of different structures to produce an effective magnetic flux density. The simulation of the magnetic flux density is carried out with the help of the COMSOL software. We have presented an optimization of the geometric parameters of the microcoil for a better performance and a miniaturization of the structure with copper wire section S=25 µm 2 and inter-wire space a=5 µm. We have also developed this microcoil by adding a ferromagnetic core to the inner center, the results obtained in this work shown that the magnetic flux density increases around 1.07 times in Bx and 1.45 times in Bz. This new approach in designing a microcoil allows to obtaining a fast trapping of the microbeads and a highly sensitive biological element detection and avoiding increase heat ratio in microfluidic systems.

Collaboration network of the authors

9 authors · 16 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Université des Sciences et de la Technologie d'Oran Mohamed Boudiaf
  • University Mohamed Boudiaf of M'sila
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Meriem DekmousAffiliation unknown2
Mustafa Ayesh Al-dhaheriUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf2
Hassan MouhadjerUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf2
Noureddine BenabadjiAffiliation unknown1
Salima DjerroudAffiliation unknown1
A. Boudghène StambouliAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Development of spiral square coils for magnetic labelling detection in microfluidic systems</dc:title><dc:creator>Feddag, Abdelhadi</dc:creator><dc:creator>Mekkakia-Maaza, Nasr-Eddine</dc:creator><dc:creator>Lakhdari, Abdelghani</dc:creator><dc:description>&lt;jats:p&gt;Due to the development of microfluidic systems biomedical microelectromechanical systems (BioMEMS) for magnetic labelling detection by magnetic microbeads circling in microfluidic channels, we used the magnetic field created by microcoils. The magnetic field associated with the electric current, but with negatively affects if its value increases too much. Handling bio-species in the microfluidic chip requires that the temperature maintained to keep the cells to prevent their destruction. In this paper we have described the spiral square coil design of different structures to produce an effective magnetic flux density. The simulation of the magnetic flux density is carried out with the help of the COMSOL software. We have presented an optimization of the geometric parameters of the microcoil for a better performance and a miniaturization of the structure with copper wire section S=25 µm&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt; and inter-wire space a=5 µm. We have also developed this microcoil by adding a ferromagnetic core to the inner center, the results obtained in this work shown that the magnetic flux density increases around 1.07 times in Bx and 1.45 times in Bz. This new approach in designing a microcoil allows to obtaining a fast trapping of the microbeads and a highly sensitive biological element detection and avoiding increase heat ratio in microfluidic systems.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i6.pp6037-6046</dc:identifier><dc:identifier>10.11591/ijece.v13i6.pp6037-6046</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 6 (2023); 6037</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/30755/16932</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>