Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Data quality processing for photovoltaic system measurements

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 1 (2024)

DOI
10.11591/ijece.v14i1.pp12-21
ISSN
2722-2578, 2088-8708
Terbit
2024-02-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The operation and maintenance activities in photovoltaic systems use meteorological and electrical measurements that must be reliable to check system performance. The International Electrotechnical Commission (IEC) standards have established general criteria to filter erroneous information; however, there is no standardized process for the evaluation of measurements. In the present work we developed 3 procedures to detect and correct measurements of a photovoltaic system based on the single diode model. The performance evaluation of each criterion was tested with 6 groups of experimental measurements from a 3 kWp installation. Based on the error of the 3 procedures performed, the most unfavorable case has been prioritized. Then, the reduction of errors between the estimated and measured value has been achieved, reducing the number of measurements to be corrected. For the clear sky categories, the coefficient of determination is 0.9975 and 0.9961 for the high irradiance profile. Although an increase of 2.5% for coefficient of determination has been achieved, the overcast sky categories should be analyzed in more detail. Finally, the different causes of measurement error should be analyzed, associated with calibration errors and sensor quality.

Jaringan kolaborasi para penulis

4 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universidad Nacional del Centro del Perú
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Armando CalcinaUniversidad Nacional del Centro del Perú3

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Data quality processing for photovoltaic system measurements</dc:title><dc:creator>Galarza, Jose</dc:creator><dc:creator>Condezo Hurtado, David</dc:creator><dc:creator>Saenz, Bartolome</dc:creator><dc:description>&lt;jats:p&gt;The operation and maintenance activities in photovoltaic systems use meteorological and electrical measurements that must be reliable to check system performance. The International Electrotechnical Commission (IEC) standards have established general criteria to filter erroneous information; however, there is no standardized process for the evaluation of measurements. In the present work we developed 3 procedures to detect and correct measurements of a photovoltaic system based on the single diode model. The performance evaluation of each criterion was tested with 6 groups of experimental measurements from a 3 kWp installation. Based on the error of the 3 procedures performed, the most unfavorable case has been prioritized. Then, the reduction of errors between the estimated and measured value has been achieved, reducing the number of measurements to be corrected. For the clear sky categories, the coefficient of determination is 0.9975 and 0.9961 for the high irradiance profile. Although an increase of 2.5% for coefficient of determination has been achieved, the overcast sky categories should be analyzed in more detail. Finally, the different causes of measurement error should be analyzed, associated with calibration errors and sensor quality.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i1.pp12-21</dc:identifier><dc:identifier>10.11591/ijece.v14i1.pp12-21</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 1 (2024); 12</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/32914/17055</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>