Fuzzy logic method-based stress detector with blood pressure and body temperature parameters

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 2 (2024)

DOI
10.11591/ijece.v14i2.pp2156-2166
ISSN
2722-2578, 2088-8708
Published
2024-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In this study, using the fuzzy logic method, a stress detection tool was created with body temperature and blood pressure parameters as indicators to determine a person's stress level. This tool uses the LM35DZ sensor to detect body temperature, the MPX5100GP sensor to read blood pressure values, and Arduino Uno as a data processor from sensor readings which are then calculated using the fuzzy logic method as a stress level decision-maker. The resulting output measures blood pressure, body temperature, and the stress level experienced by a person, which will be displayed on the liquid crystal display. Based on the results of testing the body temperature parameter, the highest error generated was 1.17%, and for the blood pressure parameter, the highest error was 2.5% for systole and 0.93% for diastole. Furthermore, testing the stress level displayed on the tool is compared to the depression, anxiety, and stress scales 42 (DASS 42), a psychological stress measuring instrument. From the results of testing the tool with the questionnaire, the average conformity level is 74%.

Collaboration network of the authors

7 authors · 13 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Muhammadiyah University of Yogyakarta
  • Rumah Sakit Umum Pusat Dr. Sardjito
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Zaipul RahmatMuhammadiyah University of Yogyakarta1
Djoko SukwonoMuhammadiyah University of Yogyakarta1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Fuzzy logic method-based stress detector with blood pressure and body temperature parameters</dc:title><dc:creator>Fajrin, Hanifah Rahmi</dc:creator><dc:creator>Sasmeri, Sasmeri</dc:creator><dc:creator>Riski Prilia, Levina</dc:creator><dc:creator>Untara, Bambang</dc:creator><dc:creator>Ahdan Fawwaz Nurkholid, Muhammad</dc:creator><dc:description>&lt;jats:p&gt;In this study, using the fuzzy logic method, a stress detection tool was created with body temperature and blood pressure parameters as indicators to determine a person's stress level. This tool uses the LM35DZ sensor to detect body temperature, the MPX5100GP sensor to read blood pressure values, and Arduino Uno as a data processor from sensor readings which are then calculated using the fuzzy logic method as a stress level decision-maker. The resulting output measures blood pressure, body temperature, and the stress level experienced by a person, which will be displayed on the liquid crystal display. Based on the results of testing the body temperature parameter, the highest error generated was 1.17%, and for the blood pressure parameter, the highest error was 2.5% for systole and 0.93% for diastole. Furthermore, testing the stress level displayed on the tool is compared to the depression, anxiety, and stress scales 42 (DASS 42), a psychological stress measuring instrument. From the results of testing the tool with the questionnaire, the average conformity level is 74%.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i2.pp2156-2166</dc:identifier><dc:identifier>10.11591/ijece.v14i2.pp2156-2166</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 2 (2024); 2156</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/33755/17293</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>